EIM Documents and Guides
System Settings / Utilities Pages
Overview
Video available for this topic: https://www.youtube.com/watch?v=GLwC7T6rGMQ
The EMIT Interface Module (EIM) provides an 8” touchscreen display and communication hub for any one module, or multiple modules, connected to the Controller Area Network (CAN) of the EIM. Modules connected to the EIM will automatically populate as buttons on the System Menu screen (Pg. 0) of the display. Selecting any of the module buttons allows for direct interaction with the respective module.
Other functions not directly related to module interaction include the system run signal trigger, security passwords and access, timer management, alarms, date and time, sensor data logging, and MODBUS communications.
The enclosure of the EIM was designed to be installed either externally using the faceplate and the base or within a panel using only the faceplate. If mounting externally, the EIM can accommodate the mounting of any one module within the base of the enclosure.
User Interface
*Need to display visual*
Display Contents And Operation
Header
- “Home” button – Navigates to home screen of currently viewed module
- “Eng” label – Indicates if valid run signal from the engine is present (“Eng: Run”) or not present (“Eng: Off”)
- Current module label – Displays the module associated with the currently viewed screen
- “Pg.” label – Displays page number associated with currently viewed screen
- “Back” button – Navigates to the previous screen
- “System Menu” button – Navigates to System Menu screen (Pg. 0)
- “Access:” button – Displays current security access level and navigates to Security Access screen (Pg. 1) to change security level
- “Timers” button – Navigates to Timer Management screen (Pg. 20) and flashes when any timer(s) require attention
- “Alarms” button – Navigates to Alarms screen (Pg. 40) and flashes when there is an active alarm
- Date/Time button – Navigates to the Date/Time screen (Pg. 2) to modify the date and time
Display Active Area
Displays content for the specific screen being viewed
Security Access
The active security access is displayed in the “Access:” button in the footer of the display. To change the security access mode, select the “Access:” button and input the password of the desired security using the keypad. Available security levels include:
Operator – Limited access to system features. No adjustments can be made.
Setup – Access to most system features and settings.
Engineering – Access to all system features including advanced adjustments.
Passwords are laser marked on the USB covers included with each system, or on a paper card. Please contact EMIT Technologies if you have lost or forgotten the passwords.
Changing Setup Password
To change the Setup password from the factory default (serial number + 10), do the following:
While in the Engineering security access mode, go to "System Settings / Utilities", and select "Change Setup Password".
Enter in the desired Setup password
Press the “Submit” button
System Settings / Utilities Pages
The "System Settings / Utilities" Page, accessed from the EIM home screen, contains several back pages for system settings. A description of each is below, or a reference to another article if it exists.
*Insert Image*
About
The About screen (Pg. 4) displays the serial number, hardware version, and software version of the EIM and each module connected to the EIM.
Touchscreen Calibration
The touch screen can be re-calibrated if it is determined that button selection appears to be offset from what is displayed on the screen. To calibrate the touch screen:
- Enter Engineering security access mode
- Navigate to the About screen (Pg. 4)
- Select the “Calibrate Touch Screen” button to start the calibration application
- Very carefully, use quick motions to touch each crosshair as they appear on the screen
- After the calibration, the screen will return to the About screen (Pg. 4) and display a confirmation box that must be accepted
- If the confirmation box is not accepted, the touch screen will omit the new calibration data
For accuracy when selecting the crosshairs, it is recommended that you use a stylus, such as the blunt end of a pen, rather than using your finger.
Use caution not to double tap or select each crosshair as it will result in a bad calibration. The best method to not double tap is to select the crosshair in one quick motion.
Go To Page
The "Go To Page" screen can be used to navigate to a page by the page number
Software Update
The "Software Update" page is used to update the software on the EIM. To use, insert a USB drive with the software update into the EIM, and click "Start Update".
Clean Screen
The "Clean Screen" page shows a blank screen so that the touch screen can be cleaned with a cloth without pressing any buttons.
Main Help
The main help button goes to the help module of the EIM. This is the same as the "Help" button on the EIM home screen.
MODBUS
The "Modbus" page is for setting up the Modbus connection. It is discussed more in-depth in the article "ETS Modbus RTU"
Config Files
The "Config Files" page can be used to save or load settings from one EIM to another. To use, insert a USB drive and click "Write" for a module or all modules. Then take the USB drive to another unit and use the same screen "Read" button to read the settings and use them on the new unit. This can speed up setup times.
Reset
In Engineering security mode, the system can be reset to the factory default values within the Reset screen (Pg. 5) of the EIM. Press the “Reset AFRC, EMD, EIM” button to reset those modules to factory defaults. Press the “Reset ICM” button to reset the Ignition to factory defaults. After reset the Ignition will be in “Configuration Required” state until ignition setup is completed.
Datalog Files
This page can be used to download or delete the datalog files. For more information, see the article "EIM Datalogging".
Home Background
This page can be used to add a background watermark to the EIM home page.
Troubleshooting File
The EIM can accept a custom troubleshooting file for showing troubleshooting trees for certain shutdown conditions. This file will usually be supplied by EMIT and uploaded on this page.
Change Setup Password
This page is used to change the setup password.
Security Key
Background
For EIM versions 1.98 and above, a special USB security key can be optionally used to lock out the "Engineering" password level of the EIM. The also DCT has very similar functionality with the same key.
The key part number is 20221-0001 -- USB SECURITY KEY F/ ETS, and can be ordered from EMIT.
The functionality is as follows:
Security Key Not Enabled
-EIM Security operates normally with passwords
Security Key Enabled
-With the security key not inserted, the user can only use 'Operator' or 'Setup' (with setup password) levels of the EIM
-With the security key inserted, the user can get to all three password levels
The security key itself can be used as a normal usb flash drive for storing files if desired- it can even be re-formatted. The security information is in un-partitioned space.
Enabling the Security Key Mode
A special USB security key (or keys) are obtained from EMIT. The key is the same for all EIMs. After inserting the key, the following dialog will automatically popup about 10 seconds later.
*Insert Image*
If "Change EIM to 'Key Required'" is selected, the EIM will change to 'Key Required' mode. Once in this mode, the key will be required to enter Engineering.
If the EIM is configured to 'Key Required' mode, the dialog will look like this when the key is inserted.
*Insert Image*
If 'Close Window' is selected, the access level can still be changed between operator, setup, and engineering if the different passwords are entered, as long as the key is in. As soon as the key is removed, the access level will return to operator, and 'engineering' level will be inaccessible. As seen in the above dialog, the 'Key Required' mode can also be turned back off with the key in.
If they EIM is in the 'Key Required' mode and the key is not inserted, the following error appears if the 'Engineering' password is entered.
*Insert Image*
Shutdown Logs
Beginning with EIM version 1.94, the EIM will save a log of sensor data for the previous 10 shutdowns, whether the shutdown was a fault or not. As new shutdowns occur, the oldest logs will be deleted so that there are never more than 10 logs.
These logs can be viewed, graphed, and downloaded (to view in Excel (R) ) just the same as the normal alarm logs are. However, there are two benefits of these logs over normal alarm logs:
- Sometimes a unit will be reset (and the alarm log cleared/deleted) before the shutdown is more thoroughly investigated. Since the last 10 shutdowns are saved, they can be still later viewed even after the alarm is cleared.
- Sometimes a unit will have a normal stop, in which case there is no alarm or alarm log, but a user may still want the shutdown data
The shutdown logs are found by selecting "Recent Shutdown Logs" on the EIM Alarms page.
*Insert Image*
EIM Alarms page- Button in lower-right shown to access recent shutdown logs
After selecting the button, a list of the last 10 shutdowns is shown.
*Insert Image*
Previous 10 shutdowns
Selecting one of the shutdowns from this list will bring up the shutdown event.
*Insert Image*
Individual shutdown event
Similar to normal alarm logs, a USB drive can be inserted on this screen to download the one minute datalog of the sensors before this shutdown. Selecting the graph allows for graphing of other sensors during the logged period.
Modbus Temporary Disable
Starting with EIM software version 2.00, the modbus can be temporary disabled during a PM to prevent inaccurate callouts during the maintenance. The system will automatically re-enable itself after a time period in case the user does not remember that modbus has been disabled.
Using Modbus Temporary Disable
To use, go to the MODBUS screen under "System Settings". If in "Engineering" password level, the disable button will be shown on the right.
*Insert Image*
After clicking 'Disable...' a confirmation dialog will come up. If 'Yes' is selected to disable, the number of hours will be asked.
*Insert Image*
The system will not respond to any modbus requests (either over serial 485 or TCP/Ethernet) until the timer expires, or the user manually re-enables the port, whichever comes first.
*Insert Image*
If the port is disabled, and the 'Disabled' button is selected, a dialog will ask the user if Modbus should be re-enabled immediately. Otherwise the timer will run out normally and re-enable automatically. The enable time is saved to disk, so the system can be power cycled multiple times and it will not affect the enabling.
Note: If the clock is changed during the disable period, it may clear the disable timer.