Software Change Log
From EMIT Controls
This page shows major changes for software updates, sorted by module.
DCT
1.66 - Not yet released
- Added standby timer adjustment, req brain 3096, found under Brain Misc Settings
- Added some new brain digital output functions
- Added TCP/Modbus to VFD connection framework. Currently testing on MV1000 drives.
- Add commissioning report under "Information"
- Add ECU pct load as a speed control option, requires latest Brain and EDT
- Added compressor ratio per alarm stage
- Fixed issue with VNC connection where the screen wouldn’t wake during the connection
- Moved pre/post-lube setup to ENG level
- Fixed a few EDT (engine) modbus discrepancies
- Add option to the blowdown on fault to wait for some time first
- Added support for remote updates (requires certain service levels)
- Added main bearing temp deviation shutdown. Requires brain 3110
1.64 25-OCT-2023
- Added ability to change engineering password under system settings
- Fixed issue where operator logs would not download if there was a space in the unit name
- Fixed issue where disabling a expansion module AI would break some random things
- Added auto-change of wifi name to append unit number (if available)
- Added pid5 setpoint reg to modbus
- Added special compressor oil pressure alarm to misc settings (req Brain 2773)
- Removed shutdown cause dialog
- Cleaned up operator log add page to show preview of full log before submitting, instead of several slides of sensor status
- Added cyls 17-20 to EDT values for 3520
- Add settings for ECU stand alone mode
- Add blowdown on normal fault option
- Add versadrive ecu option and pulse output option
- Add ao7/8 modbus regs
- Added auto restart criteria and changed layout of reset logic screen
- Add description to “Touchscreen generated alarm”
- Added icm external timing adjustment, e.g. from detonation module
1.62 07-FEB-2023
- Fix bug where ignition input info screen would not show hall moving on ecu in first box
- Made additional analysis button on alarm screen flash when shown
- Changed hourmeters to increment based on Brain ‘crank terminate rpm’ rather than fixed RPM, to accommodate low speed units
- Fixed ability to activate to ext1 service level
1.60 07-DEC-2022
- Fixed issue where speed control validation would complain about sensor 2 range incorrectly in some cases
- Add run status Brain output option
- Fix gauge select missing ECU coolant temp
- Added warning dialog if you change a setting and try to go home or back without saving
- Added modbus regs for pid loop status
- Added mass flow rate from EDT support to show on the screen
- Allow for gauge selection of ECU gauges even if there is no ECU
- Added output quick add screen for adding some loops easily
1.58 03-OCT-2022
- Fixed bug that could cause tc setup to not show asc option when it should
- Change speed control sp to be changeable in operator mode
- Add vibration sensor modbus registers
- Make sure wideband sensor is not an option on new AFRCs that are dual-rich
- Fixed bug where no flow “pct of rated” current value would only work on input 1
- Added ECU option to turn of thermistors
1.56 11-JUL-2022
- Fixed a couple ASC issues where some upper rods were still being requested, and three values were incorrectly scaled
- Changed digital valve testing screen to use diagrams for clarity
- Added manifold temp option for sharing from edt to annunciator for some loops
- Added engine de-rate option
- Added option to rename noflow 3 input
1.54 12-MAY-2022
- Added ESM2 option to EDT. Requires EDT update
- Added VNC option to ethernet setup
- Added logic for rods 5,6 to rod load (including alarm, datalog, and load ctl mode)
- Increased max valve change time to 60
1.52 03-MAR-2022
- Added manual mode to recycle pid status. Requires annunciator 2224.
- Added pints per day to the no flow monitoring.
- Added a few items to ECU info – ambient barometric pressure, intake temp, raw manifold voltage. Requires ecu 970.
- Fixed issue where the alarm file read could crash if a line had exactly 9 tokens
- Improvement to the detection of discharge temp indexes
1.50 06-JAN-2022
- Added ASC to TC input link. Requires brain version 2157.
- Change manual load button to only appear if idle hold is done
- Prevent turning on “Blowdown vent on ESD” if there is no suction block valve
- Added valve testing page
- Added config failsafe to annunciator to fault if config is blank
- Added “Restart load delay on idle” to retention file. It was previously missing.
- Fixed issue where latest CAT SPN was not actually pulled by telematics or datalog
1.48 08-NOV-2021
- Added EDT setting hints to speed control setup
- Added new CDL items to EDT table and modbus EDT table
- Added modbus option to disallow writes
- Added output option for flame detect status
- Updated load control mode so that if load calc is coming from manifold pressure it will work with GOV/ICM manifold sensor (before only worked with EDT source)
- Added DTC code to ‘Ecu-triggered’ alarms remotely for more info on what went down
- Updated alarm graph screen to show some sensors that can be scrolled through
- Added support for new AEMs that don’t have voltage mode AI/AO
- Added option to have ECU use shutdown pin only instead of CAN
- Added previous uptime to alarms
- Cleaned up valve setup screen to hide AO column normally
- Added manual mode note to valve status gauges if in manual mode
- Added text for input disabled (AI,TI) over previously blank gauges
- Some improvements to datalog graphing to show multiple lines more quickly
- Allow 0s load delay setting