Spare Parts Reference

From EMIT Controls

This page lists parts related to each module category. Navigate to a module section to see parts related to that product.

AFRC

Modules

Image EMIT P/Ns Description For Use With
20360.jpg 20360 AFRC Advanced, Single bank narrowband Single bank narrowband (richburn) applications
20230-AFRCA assembly ISO.jpg 20230 AFRC Advanced, Dual bank wideband or narrowband Single/Dual wide/narrowband applications
20230-AFRCA assembly ISO.jpg 20235 AFRC Advanced, Dual bank narrowband Single/Dual narrowband applications


O2 Sensors

Image EMIT P/Ns Description For Use With
13009.jpg 13009 Standard Narrowband O2 Sensor (4 pin) Normal richburn applications
13019.jpg 13019 Standard Wideband O2 Sensor (6 pin) Normal leanburn applications
13010.jpg 13010 Narrowband O2 Sensor to wire leads Narrowband C1D2 installation into conduit
<None> 13038 Narrowband O2 Sensor to round plug Narrowband C1D2 installation to round 4 pin plug
<None> 13020 O2 sensor weldment

Valves / DPVs

Image EMIT P/Ns Description For Use With
12013.jpg 12013 (050S) VALVE ASSY, 1/2" IN LINE
12014.jpg 12014 (075S) VALVE ASSEMBLY, 0.75" INLINE
12015.jpg 12015 (125S) VALVE ASSY, 1-1/4" IN LINE
12016.jpg 12016 (150S) VALVE ASSY, 1-1/2" IN LINE
<None> 12118 (150A) VALVE ASSY, 1-1/2" NPT X 2" DRESSER IN LINE W/RADIUSED PINTLE
<None> 12020 (150D) VALVE ASSY, 1-1/2" NPT X 2" DRESSER IN LINE
<None> 12112 (150R) VALVE ASSEMBLY, 1.50" INLINE, RADIUS PINTLE
<None> 12111 (125R) VALVE ASSY, 1-1/4" IN LINE W/RADIUSED PINTLE
<None> 12039 VALVE ASSY, 1/2" IN LINE C1D2 Same as 12013 but no plug for C1D2 install into conduit
<None> 12040 VALVE ASSY, 3/4" IN LINE C1D2 Same as 12014 but no plug for C1D2 install into conduit
<None> 12041 VALVE ASSY, 1-1/4" IN LINE C1D2 Same as 12015 but no plug for C1D2 install into conduit
<None> 12042 VALVE ASSY, 1-1/2" IN LINE C1D2 Same as 12016 but no plug for C1D2 install into conduit
<None> 12046 VALVE ASSY, 1-1/2" NPT X 2" DRESSER IN LINE C1D2 Same as 12020 but no plug for C1D2 install into conduit
<None> 12121 VALVE ASSY, 1-1/4" IN LINE W/RADIUSED PINTLE C1D2 Same as 12111 but no plug for C1D2 install into conduit
<None> 12120 VALVE ASSY, 1-1/2" IN LINE W/RADIUSED PINTLE C1D2 Same as 12112 but no plug for C1D2 install into conduit
<None> 12119 VALVE ASSY, 1-1/2" NPT X 2" DRESSER IN LINE W/RADIUSED PINTLE, C1D2 Same as 12118 but no plug for C1D2 install into conduit

Thermocouples

Image EMIT P/Ns Description For Use With
13001.jpg 13001 THERMOCOUPLE ASSY, TYPE K, 25' W/ 1/2" NPT COMPRESSION
13001.jpg 13000 THERMOCOUPLE ASSY, TYPE K, 50' W/ 1/2" NPT COMPRESSION
13001.jpg 13035 THERMOCOUPLE ASSY, TYPE K, 100' W/ 1/2" NPT COMPRESSION


Other AFRC Sensors

Caption text
Image EMIT P/Ns Description For Use With
<None> 13208 Differential pressure sensor assembly 0-1 PSI with plug Catalyst differential pressure
<None> 13207 Manifold pressure sensor assembly -30" to 30 PSI with plug Manifold pressure
13201.jpg 13201 Differential pressure sensor assembly 0-1 PSI without plug Same as 13208 but no plug for installation into conduit
13202.jpg 13202 Manifold pressure sensor assembly -30" to 30 PSI without plug Same as 13207 but no plug for installation into conduit
<None> 13204 Thermistor, 20' wire without plug, 1/4" NPT fitting Ambient temperature

AFRC Harnesses

Image EMIT P/Ns Description For Use With
<None> 15507 Wideband O2 harness, armored, 25’ EMIT 13019
<None> 15508 Wideband O2 harness, armored, 50’ EMIT 13019
<None> 15073 Narrowband O2 harness, armored, 25’ EMIT 13009
<None> 15075 Narrowband O2 harness, armored, 50’ EMIT 13009
<None> 15077 Narrowband O2 harness, armored, 100’ EMIT 13009
<None> 15087 Narrowband O2 harness, no plug, armored 25’ EMIT 13010
<None> 15088 Narrowband O2 harness, no plug, armored 50’ EMIT 13010
<None> 15089 Narrowband O2 harness, no plug, armored 100’ EMIT 13010
<None> 15137 Narrowband O2 harness for C1D2 circular plug O2 sensor 25' EMIT 13038
<None> 15138 Narrowband O2 harness for C1D2 circular plug O2 sensor 50' EMIT 13038
<None> 15139 Narrowband O2 harness for C1D2 circular plug O2 sensor 100' EMIT 13038
<None> 15072 DPV Harness, armored 25’ Any non-C1D2 valve
<None> 15074 DPV Harness, armored 50’ Any non-C1D2 valve
<None> 15076 DPV Harness, armored 100’ Any non-C1D2 valve
<None> 15087 DPV harness, no plug, armored 25’ Any C1D2 valve
<None> 15088 DPV harness, no plug, armored 50’ Any C1D2 valve
<None> 15089 DPV harness, no plug, armored 100’ Any C1D2 valve
<None> 15511 Power / Comm harness 1 ft Any module
<None> 15512 Power / Comm harness 10 ft Any module
<None> 15513 Power / Comm harness 20 ft Any module
<None> 15500 Sensor harness, armored 25’ EMIT 13207 or 12208
<None> 15501 Sensor harness, armored 50’ EMIT 13207 or 12208
<None> 15503 Sensor harness, armored 75’ EMIT 13207 or 12208
<None> 15502 Sensor harness, armored 100’ EMIT 13207 or 12208

Tetraglass

Image EMIT P/Ns Description For Use With
<None> 56066 Tetraglass tape with psa 0.75" x 1/4" x 100'
<None> 56003 Tetraglass tape with psa 1.5" x 1/8" x 100'
<None> 56005 Tetraglass tape with psa 3" x 1/8" x 100'
<None> 56007 Tetraglass tape with psa 3.5" x 1/8" x 100'
<None> 56067 Tetraglass tape with psa 1.5" x 1/8" x 100' with holes
<None> 56009 Cer-wool 3.0" x 1/2" x 25'

Speed (Governor)

Modules

Image EMIT P/Ns Description For Use With
Speed rendering.jpg 20310 Speed control module

Throttle / Mixer Assmblies

Image EMIT P/Ns Description For Use With
17011-2001.jpg 17011-2001 CAT3306NA ETB Mixer Assy 3306 NA CAT
17011-2002.JPG 17011-2002 CAT3306TA ETB Mixer Assy 3306 TA CAT
14097.jpg 14097 CAT3406 ETB Assy 3406NA CAT
<None> 14105 CAT3408TA ETB Assy 3408TA CAT
14107-0001.JPG 14107-0001 CAT3408NA ETB Assy 3408NA CAT
14085.jpg 14085 Arrow VRG330 ETB Mixer Assy VRG330
14093.jpg 14093 Arrow VRG330CF ETB Mixer Assy VRG330 CF
<None> 14122 Cummins G5.9 ETB Mixer Assy Cummins 5.9
<None> 14127 Cummins G8.3 ETB Mixer Assy Cummins 8.3
14129.jpg 14129 Cummins KTA19 ETB Assy Cummins KTA-19

Mag Pickups

Image EMIT P/Ns Description For Use With
<None> 13211 Standard 2" MPU Most small HP engines
<None> 13243 3" MPU with weatherpak plug 3400 series CAT, 300 series CAT, KTA-19

External Actuators

Image EMIT P/Ns Description For Use With
<None> 17010-0002 2040 external actuator CAT 3408 LE, 3412, other engines with external throttle
<None> 17010-0004 Linkage for 2040 17010-0002


Harnesses

Image EMIT P/Ns Description For Use With
<None> 15646 Throttle harness, armored, 25 ft Any throttle assembly under "Throttle / Mixer Assemblies"
<None> 15646-0001 Throttle harness, armored, 50 ft Any throttle assembly under "Throttle / Mixer Assemblies"
<None> 15646-0002 Throttle harness, armored, 75 ft Any throttle assembly under "Throttle / Mixer Assemblies"
<None> 15550-0002 Actuator harness, 10 pin, 50 ft armored Heiznmann 10-pin external actuator, Waukesha VHP
<None> 15625-2500 Actuator harness, 5 pin, 25 ft armored Heiznmann 5-pin external actuator (17010-0002)
<None> 15625-5000 Actuator harness, 5 pin, 50 ft armored Heiznmann 5-pin external actuator (17010-0002)
<None> 15629-0400 4 ft MPU cable f/ std MPU EMIT 13211 or 13243 Mag Pickup
<None> 15629-0800 8 ft MPU cable f/ std MPU EMIT 13211 or 13243 Mag Pickup
<None> 15629-1200 12 ft MPU cable f/ std MPU EMIT 13211 or 13243 Mag Pickup
<None> 15511 Power / Comm harness 1 ft Any module
<None> 15512 Power / Comm harness 10 ft Any module
<None> 15513 Power / Comm harness 20 ft Any module

Panel Switch Kit

Note: This is only used if installing in a non-EMIT panel

Image EMIT P/Ns Description For Use With
<None> 14361 Governor Switch Panel, Horizontal
<None> 14362 Governor Switch Panel, Vertical

Misc Governor Components

Image EMIT P/Ns Description For Use With
<None> 17113-0011 Air Cleaner Bracket, CAT3304/3304B 3304 and 3304B CAT
<None> 17413-0030 Pressure Regulator Support Bracket, CAT3304/3304B 3304 and 3304B CAT

Ignition

Modules

Image EMIT P/Ns Description For Use With
20270-ICM ISO4.jpg 20270-0002 ICM-8 Up to 8 cylinder engines
20270-ICM ISO4.jpg 20270-0003 ICM-16 Up to 16 cylinder engines

Speed and Timing Sensors

Note: Any Ignition installation will use one Flywheel mag pickup and one additional MPU or hall sensor

Image EMIT P/Ns Description For Use With
13211.jpg 13211 Standard 2" MPU Most small HP engines
13242.jpg 13242 3" MPU to circular connector 3400, 300 series CAT , KTA-19
13240-0001.jpg

Note: Above image doesn't show bracket and screw || 13240-0002 || 330x Hall sensor and bracket || 3304B, 3306B CAT

<None> 13241 5/8" Threaded hall sensor 3400 CAT, Waukesha VHP, Cummins engines if a bushing is used
<None> 13264 M12 threaded hall sensor Timing disc kit, eg 3306A
<None> 65300-6282-A 3/4 to 5/8 bushing Cummins engines to adapt 13241 to the engine
<None> 20290-0003 Aux Pickup, 3:1 3300 A CAT, 398 CAT
<None> 20290-0002 Aux Pickup, 2:1 399 CAT, 379 CAT, 3400 CAT, 3500 CAT

Speed and Timing Harnesses

Image EMIT P/Ns Description For Use With
<None> 15629-0400 4 ft MPU cable f/ std MPU EMIT 13211
<None> 15629-0800 8 ft MPU cable f/ std MPU EMIT 13211
<None> 15629-1200 12 ft MPU cable f/ std MPU EMIT 13211
<None> 15654-0800 8 ft MPU cable f/ long MPU EMIT 13242
<None> 15654-1200 12 ft MPU cable f /long MPU EMIT 13242
<None> 15654-1600 16 ft MPU cable f /long MPU EMIT 13242
<None> 15654-2000 20 ft MPU cable f /long MPU EMIT 13242
<None> 15620-0400 Hall sensor harness, 330xB, 4 ft EMIT 13240-0002
<None> 15620-0800 Hall sensor harness, 330xB, 8 ft EMIT 13240-0002
<None> 15620-1200 Hall sensor harness, 330xB, 12 ft EMIT 13240-0002
<None> 15628-0450 Hall sensor harness, 4.5 ft EMIT 13241 or 13264
<None> 15628-1000 Hall sensor harness, 10 ft EMIT 13241 or 13264
<None> 15637-0040 Cummins MPU harness, 4 ft Stock Cummins Timing Sensor
<None> 15637-0080 Cummins MPU harness, 8 ft Stock Cummins Timing Sensor
<None> 15637-0120 Cummins MPU harness, 12 ft Stock Cummins Timing Sensor
<None> 15637-0160 Cummins MPU harness, 16 ft Stock Cummins Timing Sensor
<None> 15650-0800 Aux Pickup harness, 8 ft EMIT Aux Pickups
<None> 15650-1200 Aux Pickup harness, 12 ft EMIT Aux Pickups 
<None> 15650-1600 Aux Pickup harness, 16 ft EMIT Aux Pickups

Power/Comm Harness

The power/comm harness is used to connect the ICM to the panel. The unarmored version might be more convenient if running through conduit.

Image EMIT P/Ns Description For Use With
<None> 15633-0251 ICM Power/Comm harness, armored, 25 ft Any ICM
<None> 15633-0501 ICM Power/Comm harness, armored, 50 ft Any ICM
<None> 15633-0250 ICM Power/Comm harness, unarmored, 25 ft Any ICM
<None> 15633-0500 ICM Power/Comm harness, unarmored, 50 ft Any ICM

Coil harnesses

Image EMIT P/Ns Description For Use With
<None> 15639-4120 ICM 4-cyl harness A  
<None> 15639-4001 ICM 4-cyl harness B CAT 3304
<None> 15639-6120 ICM 6-cyl harness A  
<None> 15639-6093 ICM 6-cyl harness B  
<None> 15639-6068 ICM 6-cyl harness C  
<None> 15639-6001 ICM 6-cyl harness D CAT 3306
<None> 15639-6043 ICM 6-cyl harness E  
<None> 15639-6065 ICM 6-cyl harness F Cummins KTA19
<None> 15639-6095 ICM 6-cyl harness G CAT 3406
<None> 15639-8120 ICM 8-cyl harness A CAT 3408
<None> 15639-8150 ICM 8-cyl harness B CAT 379
<None> 15639-1215 ICM 12-cyl harness A CAT 398

Ignition Coils

Image EMIT P/Ns Description For Use With
14330-0001.jpg 14330-0001 Standard ignition coil
<None> 14330-0002 Flanged ignition coil Waukesha VHP

Secondaries

Image EMIT P/Ns Description For Use With
<None> 14332-0001 Spark Plug Wire, 12in Lead, 4in Est, 7mm, Str/Str F/ CAT 3300 3300 CAT
<None> 14332-0007 Secondary Lead, Resistive Suppression, CAT 3400 3400 CAT
<None> 14332-0005 Secondary Lead, Resistive Suppression, ARROW VRG330 Arrow VRG 330
<None> 14332-0008 Secondary Lead, Resistive Suppression, Cummins G5.9 Cummins 5.9
<None> 14332-0009 Secondary Lead, Resistive Suppression, Cummins G8.3 Cummins 8.3
<None> 14332-0010 Secondary Lead, Resistive Suppression, Cummins KTA19 Cummins KTA19
<None> 14092-0001 Cat300 ignition secondary CAT 398 (To be confirmed)
<None> 14332-0011 SECONDARY LEAD, RESISTIVE SUPPRESSION, CUMMINS G/GTA855  G/GTA855
<None> 14332-0012 SECONDARY LEAD, RESISTIVE SUPPRESSION, ARROW VRG220  VRG220

Spark Plugs

Image EMIT P/Ns Description For Use With
<None> 14331-0001 Spark plug 14mm x 19mm 3300 CAT, VRG330,
<None> 14331-0005 Spark plug f/ CAT 3400 3400 CAT
<None> 14331-0006 Spark plug f/ Cummins 5.9 Cummins 5.9
<None> 14331-0007 Spark plug f/ Cummins 8.3 Cummins 8.3
<None> 14331-0008 Spark plug f/ Cummins KTA19 Cummins KTA19

Mount Brackets

Image EMIT P/Ns Description For Use With
<None> 14306 Universal Skid mount Any application not listed below
<None> 14305-0002 ICM1 Mount kit, 330xB CAT 3304B,3306B

ECU

Modules

Image EMIT P/Ns Description For Use With
Ecu-rendering.jpg 20390 ECU Module

Engine End Devices

For Mixer assemblies, see above

For ignition mag pickups and hall sensors, see above

For ignition coils see above

For ignition secondaries see above

For ignition spark plugs see above

For O2 sensors see above

For DPVs see above

Image EMIT P/Ns Description For Use With
<None> 13062-0001 Thermocouple 3' to quick disconnect Pre/Post cat temp on ECU
<None> 13063 ECU Manifold Pressure sensor
<None> 13064 ECU Oil Pressure sensor
<None> 13255-0001 Thermistor to 1/4" NPT Coolant and Oil temp

ECU Coil Harness

Image EMIT P/Ns Description For Use With
<None> 15657-0001 ECU Coil Harness 6 cyl 33" 3306B, G855, QSL9
<None> 15657-0003 ECU Coil Harness 6 cyl 54" 3306A
<None> 15657-0005 ECU Coil Harness KTA19 KTA19

ECU Panel Harnesses

The panel harness runs from the ECU back to the panel. The length required depends on how far the ECU is mounted from the panel.

Image EMIT P/Ns Description For Use With
<None> 15656-0001 ECU Panel Harness 20'
<None> 15656-0002 ECU Panel Harness 10'
<None> 15656-0003 ECU Panel Harness Injection only 10'
<None> 15656-0004 ECU Panel Harness 28'

ECU Engine Harness

Note: Another page shows connector pinouts and parts here: ECU_Connector_Pinouts

Image EMIT P/Ns Description For Use With
<None> 15655-0001 ECU Engine Harness 3306B NA 330xB NA
<None> 15655-0003 ECU Engine Harness 3306A TA 330xA TA, hall sensor used for CAM disc
<None> 15655-0004 ECU Engine Harness 3306B TA 330xB TA
<None> 15655-0005 ECU Engine Harness G855 G855
<None> 15655-0006 ECU Engine Harness KTA-19 KTA-19
<None> 15655-0007 ECU Engine Harness QSL9 QSL9
<None> 15655-0008 ECU Engine Harness 330xA NA 330x NA, hall sensor used for CAM disc

ECU Exhaust Harness

For a given engine, the exhaust harness that will be needed depends on what catalyst is used and how it is arranged. Note the lengths mentioned below to help select the harness.

Image EMIT P/Ns Description For Use With
<None> 15658-0001 ECU Exhaust Harness, manifold mount catalyst, 6' pre / 8' post Manifold mount catalyst
<None> 15658-0002 ECU exhaust harness, 5' pre O2, 26' post Pre O2 near engine and Post O2 + TCs at cooler
<None> 15658-0003 ECU exhaust harness, 15' Pre O2, 28' Post Pre O2 near engine and Post O2 + TCs at cooler
<None> 15658-0004 ECU exhaust harness, 31' All sensors at 31'
<None> 15658-0005 ECU exhaust harness, 26' All sensors at 26'

Panel

Panserts

The pansert is what goes on the inner door to accept the engine control box.

Image EMIT P/Ns Description For Use With
64595-0101.JPG 64595-0101 G3500A3 PANSERT GROUP Ps0101T.jpg
64595-0102.JPG 64595-0102 G3600A3 PANSERT GROUP Ps0102T.jpg
64595-0103.JPG 64595-0103 G3500A4 PANSERT GROUP Ps0103T.png
64595-0104.jpg 64595-0104 G3300A4 PANSERT Ps0104T.jpg
64595-0105.JPG 64595-0105 CG-137 OCP PANSERT Ps0105T.JPG
64595-0112.JPG 64595-0112 CG-137 A4-E4 PANSERT GROUP Ps0112T.JPG
64595-0180.JPG 64595-0180 G3600A4 HMI FULL ENCLOSURE (ENCINF2 578-8670) PANSERT GROUP Ps0180T.jpg
64595-0188.jpg 64595-0188 ESM2 Pansert
64595-0198.JPG 64595-0198 G3600A4 BASE HMI (BASE8HMI 578-8668) PANSERT GROUP HMI components with no box Ps0198T.png
64595-1017.jpg 64595-1021 ASC Pansert
64595-1022.jpg 64595-1022 15" ESM2 Pansert
64595-1023.png 64595-1023 19" ESM2 Pansert Esm2.jpg

Pressure Sensors

Panel Mounted (to wire leads)

Image EMIT P/Ns Description For Use With
<None> 13202 PRESSURE TRANSDUCER, -14.7 to +30 PSIG Manifold Pressure
<None> 13050 PRESSURE TRANSDUCER, 0-100 PSIG
<None> 13051 PRESSURE TRANSDUCER, 0-300 PSIG
<None> 13052 PRESSURE TRANSDUCER, 0-500 PSIG
<None> 13053 PRESSURE TRANSDUCER, 0-1000 PSIG
<None> 13054 PRESSURE TRANSDUCER, 0-1500 PSIG
<None> 13055 PRESSURE TRANSDUCER, 0-2000 PSIG
<None> 13056 PRESSURE TRANSDUCER, 0-3000 PSIG
<None> 13069 PRESSURE TRANSDUCER, 0-5 PSIG

Remote Mounted (With plug)

Image EMIT P/Ns Description For Use With
<None> 13207 PRESSURE TRANSDUCER, -14.7 to +30 PSIG WITH PLUG Manifold Pressure
<None> 13244 PRESSURE TRANSDUCER, 0-100 PSIG WITH PLUG
<None> 13245 PRESSURE TRANSDUCER, 0-300 PSIG WITH PLUG
<None> 13246 PRESSURE TRANSDUCER, 0-500 PSIG WITH PLUG
<None> 13247 PRESSURE TRANSDUCER, 0-1000 PSIG WITH PLUG
<None> 13248 PRESSURE TRANSDUCER, 0-1500 PSIG WITH PLUG
<None> 13249 PRESSURE TRANSDUCER, 0-2000 PSIG WITH PLUG
<None> 13250 PRESSURE TRANSDUCER, 0-3000 PSIG WITH PLUG
<None> 13259 PRESSURE TRANSDUCER, 0-5 PSIG WITH PLUG

Pressure Sensor Harnesses, for above remote mounted option

Image EMIT P/Ns Description For Use With
<None> 15500 SENSOR HARNESS 25 FT ARMORED
<None> 15501 SENSOR HARNESS 50 FT ARMORED
<None> 15503 SENSOR HARNESS 75 FT ARMORED
<None> 15502 SENSOR HARNESS 100 FT ARMORED

Other End Devices

Image EMIT P/Ns Description For Use With
13001.jpg 13001 THERMOCOUPLE ASSY, TYPE K, 25' W/ 1/2" NPT COMPRESSION 
13001.jpg 13000 THERMOCOUPLE ASSY, TYPE K, 50' W/ 1/2" NPT COMPRESSION 
13001.jpg 13035 THERMOCOUPLE ASSY, TYPE K, 100' W/ 1/2" NPT COMPRESSION 
<None> 13001-0001 THERMOCOUPLE ASSY, TYPE K, 25' W/ 1/4" NPT COMPRESSION 
<None> 13000-0001 THERMOCOUPLE ASSY, TYPE K, 50' W/ 1/4" NPT COMPRESSION  
<None> 13029  FITTING, 1/2" NPT THERMOCOUPLE COMPRESSION FITTING  
<None> 13029-0001 THERMOCOUPLE COMPRESSION FITTING 1/4" NPT  
<None> 13060 THERMOWELL, HEAVY DUTY, 1/2" NPT, 6" LENGTH, 316 STAINLESS  
<None> 13017  THERMOCOUPLE, TYPE K, 25' (no compression fitting)  
<None> 13016  THERMOCOUPLE, TYPE K, 50' (no compression fitting)  
<None> 13034 THERMOCOUPLE, TYPE K, 100' (no compression fitting)  
<None> 13061  THERMOCOUPLE, TYPE K, 25' STRAIGHT                                      
<None> 13036  THERMOCOUPLE ASSY, STRAIGHT, TYPE K, 25' W/ 1/2" NPT COMPRESSION 
<None> 13062  THERMOCOUPLE, TYPE K, 3' 

Panel Internal Parts

Image EMIT P/Ns Description For Use With
<None> 14412-0003 Terminal block relay, C1D2 All 24v panels
<None> 14412-0004 Solid state (main power) relay, 12A
<None> 14412-0006 Terminal block relay, C1D2, 12v All 12v panels
<None> 14412-0008 Terminal block relay, C1D2, 24v DPDT Not commonly used, double pole
<None> 14406-0002 TERMINAL BLOCK, DOUBLE LEVEL
<None> 14406-0005 TERMINAL BLOCK, TRIPLE LEVEL
<None> 14406-0004 TERMINAL BLOCK JUMPER, DOUBLE TB, 10 POLE
<None> 14406-0004 TERMINAL BLOCK JUMPER, DOUBLE TB, 2 POLE, TRIMMED
<None> 14406-0004 TERMINAL BLOCK JUMPER, DOUBLE TB, 8 POLE, TRIMMED
<None> 14406-0004 TERMINAL BLOCK JUMPER, DOUBLE TB, 9 POLE, TRIMMED
<None> 14439 DIODE, TERMINAL BLOCK
<None> 14428 Fuse Holder, 1-1/4"x1/4", 30A, 600V
<None> 20132 DIN Rail Stop
<None> 14429-0001 Fuse, 1A Fast blow ceramic 1/4" x 1-1/4"
<None> 14429-0002 Fuse 2A
<None> 14429-0005 Fuse 5A
<None> 14429-0008 Fuse 8A
<None> 14429-0020 Fuse 20A
<None> 14425 SWITCH, DOOR INTERLOCK, SPDT, C1D2 Door light switch
<None> 14389-0006 PUSH BUTTON, 30MM, 1xNO, SPRING RETURN, BLACK, C1D2 Reset switch
<None> 14389-0005 PUSH BUTTON, 30MM, 1xNO, SPRING RETURN, GREEN, C1D2 Start switch
<None> 14389-0007 PUSH BUTTON, 30MM, 1xNC, SPRING RETURN, RED, C1D2 Stop switch
<None> 14415 EMERGENCY STOP BUTTON, 30MM, C1D2 E-Stop
<None> 14425-0007 SEL SW, 1xNO, MAINTAINED, 2 POS Power switch
<None> 14425-0005 SEL SW, 2xNO, MAINTAINED, 3 POS Speed mode select switch
<None> 14425-0006 SEL SW, 2xNO, SPRING RETURN, 3 POS, BLACK, C1D2 Speed +/- switch
<None> 14388-0001 LIGHT TOWER DOME, C1D2
<None> 14440-0001 LIGHT TOWER DOME HARNESS, C1D2
<None> 14408 6 POSITION GROUND LUG BAR
<None> 20374-0001 ANTENNA, RF, CELL, WIFI, GPS
<None> 14431-0004 LED LIGHT BAR, C1D2
<None> 14388-0002 PANEL MOUNT, BUZZER, HORN, C1D2
<None> 20165-0001 PANEL FUSE AND FERRULE REPLACEMENT GROUP
<None> 14425-0008 CONTACT BLOCK-LRNO-C1D2, LOGIC REED, H. SEALED, 1NO LRNO

Mount Kits

Mount kits are used if installing component(s) on non-EMIT Panels

Image EMIT P/Ns Description For Use With
14205.jpg 14205 Mount Kit, Module Panel Mounting a module in a panel
14206.jpg 14206 Mount Kit, Module EIM Mounting a module in an EIM outdoor enclosure
14200.jpg 14200 EIM Panel Mount Kit Mounting an EIM in a panel
14201.JPG 14201 EIM indoor mount Kit Mounting an EIM to side of panel
14202.jpg 14202 EIM outdoor mount Kit Mounting an EIM to side of panel, with rain cover