DCT Password Levels
From EMIT Controls
Revision as of 21:45, 6 February 2023 by Thomas Peterson (talk | contribs)
The DCT has three password levels: read-only, Setup, and Engineering. The list below shows which settings groups are included under each level.
Note: some uncommon settings are not shown
Settings that can be changed under read-only
- PID Setpoint/Deadband (if enabled on PID setup page)
- Speed setpoint
Settings that can be changed under Setup
- Engine hour timers reset
- AFRC Alarms
- Analog input kills (but not sensor settings)
- Digital input setup
- B timer lengths
- Buzzer alarm
- Custom digital output criteria
- Brain ECU selection
- Gauge setup
- Idle hold settings
- Speed alarms
- Load delay settings
- Pre/Post lube settings
- Noflow settings
- Recycle loop settings (some settings)
- Speed de-rate settings
- Start gas settings
- Thermocouple input kills
- EMIT Ignition alarms, calibration, timing setup
- EMIT Speed controller Alarm setup, idle hold setup, sensor setup, calibration
- EMIT Vibration sensor kill level
Settings that can be changed under Engineering
Everything else