All public logs

From EMIT Controls

Combined display of all available logs of EMIT Controls. You can narrow down the view by selecting a log type, the username (case-sensitive), or the affected page (also case-sensitive).

Logs
  • 17:15, 2 July 2024 Thomas Peterson talk contribs created page EDR Troubleshooting - Engine data issues (Created page with "Symptom: There is missing engine data on the site but compressor data is working ==Verify Wiring== 1. The EDR will have wires from pin 9,10 of the module to the pink and purple wires in the CAT panel (A3 only) 2. The EDR will have wires from pin 13, 14 of the module to the green and yellow wires in the CAT panel Verify CAN termination 3. There is a CAN termination switch next to pin 14 of the EDR. If this is ON (to outside of module) then the CAT termination resistor...")