  • 20:14, 21 July 2022 Sean Sanders talk contribs created page ECU Manual (Created page with "The ECU manual can be viewed/downloaded here: https://drive.google.com/open?id=14KyeKD9hayM4SeIV7c8Ia0Z-tWnjZUkZ") Tag: Visual edit
  • 19:15, 21 July 2022 Sean Sanders talk contribs created page AFRC Setup (Created page with "Video available for this topic: https://www.youtube.com/watch?v=PAmjcq7CPt0 === ENGINE CONDITION === For proper AFRC operation, it is critical that the engine be in good operational status. Verify the following before running the AFRC: * Valves are adjusted to factory specification * Spark plugs are properly gapped and in good condition * Cylinders have good compression * Mixers are in good condition and regulator fuel pressure is set to factory specification * Fuel co...") Tag: Visual edit
  • 18:37, 21 July 2022 Sean Sanders talk contribs created page AFRC Home Screen (Created page with "The AFRC Home screen provides all the necessary information and functionality to select the target setpoint, adjust the valve, enable/disable control, and access additional setup features. The left side of the screen is broken up into boxes which represent control for the individual banks of the engine. The right side of the screen provides a visual indication, through bar graphs, of the oxygen content of the exhaust, valve position, and catalyst temperatures. A security...") Tag: Visual edit
  • 18:34, 21 July 2022 Sean Sanders talk contribs created page AFRC Installation Guide (Created page with "The installation guide can be downloaded here: https://drive.google.com/open?id=1UkusWWJOSeBmjavjdAVOUHR_ocauA2Z1 The quick start guide can be downloaded here: https://drive.google.com/file/d/0BzOiNHLPWdg1UXlaX2YzOFM0dms/view?usp=sharing&resourcekey=0-c9itYJbFwTwDKjlhv3kEDg") Tag: Visual edit
  • 18:27, 21 July 2022 Sean Sanders talk contribs created page EIM Software Update (Created page with "Video available for this topic: https://www.youtube.com/watch?v=o9Mf76GIxBA * Using a Windows-based computer, transfer the EMIT-provided EIM software update file to a FAT-formatted USB thumb drive * The file name should be “EIM_update.tar” * Plug the USB thumb drive into the USB A port on the opposite side of the EIM * Within the EIM’s user interface, enter the appropriate password to for either Setup or Engineering security access * From the System Menu screen (...") Tag: Visual edit
  • 18:25, 21 July 2022 Sean Sanders talk contribs created page EIM Alarms (Created page with "The EIM and associated modules are capable of identifying a wide range possible alarm conditions. Depending on the module there are a set of custom and fixed alarms in the system to generate an alarm event for the error condition. See the “ALARMS” section of any of the modules for details on how to configure an alarm. As discussed in the module alarm sections, most alarms can be set up to close the error relay and shutdown the engine on critical alarms (other than an...") Tag: Visual edit
  • 18:17, 21 July 2022 Sean Sanders talk contribs created page EDR Wi-Fi Console Pages (Created page with "From the top right menu on a phone, or along the top on a computer, there will be the following page categories: Status, Compressor Master, Alerts, Engine Data Translator, Modbus Slave, and Debug. Each of these 6 pages are detailed below. === Status === The Status page shows the current readings for engine and compressor data. Settings cannot be edited on this page. Also shown under “General” is the serial number and software version. <nowiki>*</nowiki>Insert Image...") Tag: Visual edit
  • 18:12, 21 July 2022 Sean Sanders talk contribs created page EDR Connecting (Created page with "Check your target device’s Wi-Fi settings for a network called “EDR_xxxx”, where xxxx is the serial number of the Data Relay. Connect to this network and enter the password ‘emitemit’. Note: There will be no internet access while you are connected to the network. It is recommended that you turn auto reconnect off. Once connected, open a web browser and type <nowiki>http://172.16.16.1/</nowiki> . This will bring up the Data Relay console. <nowiki>*</nowiki>In...") Tag: Visual edit
  • 18:11, 21 July 2022 Sean Sanders talk contribs created page EDR Troubleshooting Guide (Created page with "This document covers troubleshooting steps for various EDR issues https://drive.google.com/file/d/1-gnsQWNj71XOUQYHcC5wN2dpd5X-1Hr6/view?usp=sharing") Tag: Visual edit
  • 18:11, 21 July 2022 Sean Sanders talk contribs created page EDR Internal EDT Update (Created page with "The EDR has an internal EDT that is updated separately from the EDR itself. It is uncommon that it needs to be updated, but if it does follow these steps. 1. Download the latest EDT_xxxx.hex file from this page 2. Put the file on a USB drive 3. Remove the cover of the EDR by loosening the screws on one of the end caps 4. Locate the USB port near the power switch that was previously hidden <nowiki>*</nowiki>Insert Image* ''USB port location'' 5. Turn power o...") Tag: Visual edit
  • 18:10, 21 July 2022 Sean Sanders talk contribs created page EDR Installation Guide (Created page with "There are install guides for different types of panels that shows the specific details for that type. The currently available install guide links are below. New combined document: https://drive.google.com/file/d/1TUEDAemMng3xTDCwqNSy16d1HOJxVciA/view?usp=sharing Murphy TTD: https://drive.google.com/file/d/1HAgyOSzoLrYLllkaGtimA7d615ya94mX/view?usp=sharing Murphy Centurion C4: https://drive.google.com/file/d/1tuuhHGA9hmNi1F7u8UZXB_T4W_WQ0ZDw/view?usp=sharing Altronic...") Tag: Visual edit
  • 18:08, 21 July 2022 Sean Sanders talk contribs created page EDR Field Configuration (Created page with "Video for this topic: https://www.youtube.com/watch?v=y2lrFy0ITbQ Generally EMIT will send out the EDR already configured to communicate via Modbus to a specific panel. If the module is not configured, the guides below detail how to configure the module for a type of panel. Configuring for DE3000 Panel: https://drive.google.com/file/d/1dyrNdjfzIoRU_jQudMkycjfdVLv5qpE9/view?usp=sharing Configuring for DD40 Panel: https://drive.google.com/file/d/1ezXo-FjjVbN7KEMYP_QOT_...") Tag: Visual edit
  • 17:53, 21 July 2022 Sean Sanders talk contribs created page Auto Override (Created page with "In some cases, it is useful to have the governor go to full speed during a pressure-control mode to anticipate an upcoming load change. The governor auto override allows for this. In general, starting the override mode causes the governor to enter full speed for a given time period (e.g. 3 minutes). Once this time period expires, the governor returns to normal control mode. The timer will start and count down regardless of control mode, but if the governor is not runni...") Tag: Visual edit
  • 17:52, 21 July 2022 Sean Sanders talk contribs created page Throttle Calibration (Created page with "The Governor Throttle Calibration page (Pg. 523) can be used to re-calibrate the throttle body. This moves the throttle through its full range of motion and saves the values for the endpoints and also what effort is required to move the throttle. To get to this page, from the Governor Home Screen select "Setup" followed by "Throttle Calibration". The throttle will usually only need to be recalibrated if the throttle is changed. It could also help to recalibrate it if it...") Tag: Visual edit
  • 17:51, 21 July 2022 Sean Sanders talk contribs created page Engineering Setup (Created page with "The Governor Advanced Setup page (Pg. 521) contains advanced settings for governor operation. An access level of ''Engineering'' is needed to use this page. A description of each setting is listed below. <nowiki>*</nowiki>Insert Image* ''Governor Advanced Setup'' Starting RPM: This is the value which the Governor uses to determine if the engine is done cranking. It would not likely need to be changed unless an engine cranks very quickly. Starting Throttle: This is th...") Tag: Visual edit
  • 17:50, 21 July 2022 Sean Sanders talk contribs created page Sensor Setup (Created page with "The Governor Sensor Setup page (Pg. 520) specifies the pressure sensor settings. This duplicates the functionality on setup step 4. An access level of Setup or higher is needed to see this screen. For each sensor used, specify the low and high PSI value that corresponds to the input that causes an output of 4mA and 20mA respectively. This information can be found stamped on the sensor itself.") Tag: Visual edit
  • 17:46, 21 July 2022 Sean Sanders talk contribs created page Sensor Status Screen (Created page with "The Governor Sensors screen (Pg. 505) shows the current status of sensors connected to the Governor. The screen shows the RPM, throttle position, and battery voltage. Also shown are the pressure inputs, if attached. The scaling of the pressure sensors can be specified on the Sensor Setup screen, discussed later. <nowiki>*</nowiki>Insert Image*") Tag: Visual edit
  • 17:43, 21 July 2022 Sean Sanders talk contribs created page Modes Of Operation (Created page with "=== Modes Of Operation === The user can select through the panel’s mode switch either “Idle,” “Manual,” or “Auto” (Run) mode for the Governor. Additionally, Auto mode can be setup to function in various ways. A description of each control mode is provided below. ==== IDLE ==== When the panel’s mode switch is in Idle, the Governor will hold the engine at the user-specified idle speed. This speed is specified during governor setup, described in a later sec...") Tag: Visual edit
  • 17:36, 21 July 2022 Sean Sanders talk contribs created page Run Signal Trigger and System Temperature Units (Created page with "The run signal trigger and system temperature units are configured on the Run Signal Trigger screen (Pg. 10) of the EIM, which can be accessed under the AFRC Setup page (Pg. 201). The AFRC uses one of seven possible methods to recognize if an engine is running. The available sensors to trigger the run signal are below. * Auto-Detect (Default) * Scans all other run-signal sources for conditions indicating the engine is running * AFRC Pre-Catalyst Thermocouple * AFRC Adv...") Tag: Visual edit
  • 17:33, 21 July 2022 Sean Sanders talk contribs created page Map Setup (Created page with "The AFRC features the ability for the target setpoint to automatically adjust based on changes to environmental conditions or sensor readings. This is accomplished by building a table, or map, that associates multiple target setpoints to a set of sensor conditions. As the sensor readings change, an offset can be applied to the target setpoint so that it changes autonomously. This feature can be used to account for environmental factors or load swings that may affect the...") Tag: Visual edit
  • 17:32, 21 July 2022 Sean Sanders talk contribs created page Engineering Adjustments (Created page with "While in ''Engineering'' security mode, the Engineering Setup screen (Lite Pg. 304, Adv. Pg. 207) is available through the Setup screen (Lite Pg. 301, Adv. Pg. 201). This screen provides access to gain adjustment and other engine configuration settings. <nowiki>*</nowiki>Insert Image* AFRC Engineering Setup Screen === GAIN ADJUSTMENT === The AFRC operates on a PID control loop to automatically adjust the valve to match the actual sensor reading to the target setpoint....") Tag: Visual edit
  • 17:28, 21 July 2022 Sean Sanders talk contribs created page Auto Control Range Alarm (Created page with "If AutoControl is used on the AFRC Advanced, the final alarm in the Alarms Setup screen (Pg. 206) is the “AutoControl Range” alarm. This alarm can be used to fall back from “AutoControl” to “Setpoint” mode in the event the Post Catalyst O2 sensor milliVolt reading is pushed outside the set range, which can indicate the sensor is failing. On a trigger of the alarm condition, the AFRC will go into “Setpoint” mode with a target setpoint valve defined by the...") Tag: Visual edit
  • 17:25, 21 July 2022 Sean Sanders talk contribs created page Setup (Created page with "Video available for this topic: https://www.youtube.com/watch?v=PAmjcq7CPt0 === ENGINE CONDITION === For proper AFRC operation, it is critical that the engine be in good operational status. Verify the following before running the AFRC: * Valves are adjusted to factory specification * Spark plugs are properly gapped and in good condition * Cylinders have good compression * Mixers are in good condition and regulator fuel pressure is set to factory specification * Fuel co...") Tag: Visual edit
  • 17:23, 21 July 2022 Sean Sanders talk contribs created page Home Screen (Created page with "The AFRC Home screen provides all the necessary information and functionality to select the target setpoint, adjust the valve, enable/disable control, and access additional setup features. The left side of the screen is broken up into boxes which represent control for the individual banks of the engine. The right side of the screen provides a visual indication, through bar graphs, of the oxygen content of the exhaust, valve position, and catalyst temperatures. A security...") Tag: Visual edit
  • 17:22, 21 July 2022 Sean Sanders talk contribs created page Installation Guide (Created page with "The installation guide can be downloaded here: https://drive.google.com/open?id=1UkusWWJOSeBmjavjdAVOUHR_ocauA2Z1 The quick start guide can be downloaded here: https://drive.google.com/file/d/0BzOiNHLPWdg1UXlaX2YzOFM0dms/view?usp=sharing&resourcekey=0-c9itYJbFwTwDKjlhv3kEDg") Tag: Visual edit
  • 17:13, 21 July 2022 Sean Sanders talk contribs created page User Interference (Created page with "<nowiki>*</nowiki>Need to display visual* === Display Contents And Operation === ==== Header ==== * “Home” button – Navigates to home screen of currently viewed module * “Eng” label – Indicates if valid run signal from the engine is present (“Eng: Run”) or not present (“Eng: Off”) * Current module label – Displays the module associated with the currently viewed screen * “Pg.” label – Displays page number associated with currently viewed scr...") Tag: Visual edit
  • 17:03, 21 July 2022 Sean Sanders talk contribs created page Modbus Temporary Disable (Created page with "Starting with EIM software version 2.00, the modbus can be temporary disabled during a PM to prevent inaccurate callouts during the maintenance. The system will automatically re-enable itself after a time period in case the user does not remember that modbus has been disabled. === Using Modbus Temporary Disable === To use, go to the MODBUS screen under "System Settings". If in "Engineering" password level, the disable button will be shown on the right. <nowiki>*</nowik...") Tag: Visual edit
  • 17:02, 21 July 2022 Sean Sanders talk contribs created page Shutdown Logs (Created page with "Beginning with EIM version 1.94, the EIM will save a log of sensor data for the previous 10 shutdowns, whether the shutdown was a fault or not. As new shutdowns occur, the oldest logs will be deleted so that there are never more than 10 logs. These logs can be viewed, graphed, and downloaded (to view in Excel (R) ) just the same as the normal alarm logs are. However, there are two benefits of these logs over normal alarm logs: * Sometimes a unit will be reset (and the...") Tag: Visual edit
  • 17:01, 21 July 2022 Sean Sanders talk contribs created page Security Key (Created page with "=== Background === For EIM versions 1.98 and above, a special USB security key can be optionally used to lock out the "Engineering" password level of the EIM. The also DCT has very similar functionality with the same key. The key part number is 20221-0001 -- USB SECURITY KEY F/ ETS, and can be ordered from EMIT. The functionality is as follows: Security Key Not Enabled ''-''EIM Security operates normally with passwords ''Security Key Enabled'' -With the security ke...") Tag: Visual edit
  • 17:00, 21 July 2022 Sean Sanders talk contribs created page Ethernet (Created page with "=== Overview === Some EIMs have an ethernet port on the back that can be connected to a customer network. The following serial number ranges have an ethernet port: * 1000 - 1899 * 3203 and newer The following functions are currently supported by the ethernet port: * Modbus TCP (EIM Versions 1.89 and later) Other functions, such as file transfers and remote web access, may be supported in the future. This page covers the setup of the ethernet port. === Ethernet Setu...") Tag: Visual edit
  • 16:58, 21 July 2022 Sean Sanders talk contribs created page SD Or Boot Issues (Created page with "For addressing and preventing EIM Boot issues, see this document: https://drive.google.com/open?id=0BzOiNHLPWdg1WktkRnNsWmNQdGM") Tag: Visual edit
  • 16:57, 21 July 2022 Sean Sanders talk contribs created page Open Source Software Notice (Created page with "The software included in this product contains proprietary and confidential copyrighted software developed and owned by EMIT Technologies, Inc. which is distributed subject to the Software License Agreement located in "APPENDIX H. SOFTWARE LICENSE AGREEMENT" of the user manual. This product, and any connected EMIT modules, also include copyrighted open source software that is licensed under the GPL, including FreeRTOS v7.0.1, copies of which are located in "APPENDIX I....") Tag: Visual edit
  • 16:56, 21 July 2022 Sean Sanders talk contribs created page Notes Page (Created page with "Notes allows manual text documentation for periodic maintenance, emissions testing, catalyst maintenance, part replacement, status records, or any other event. Reach the notes page by selecting "Notes" from the EIM Home Screen. To enter a note, press the “Add” button and type in the note using the on screen keyboard. This function is available in all access levels. After the note is added, the first several words of the note can be viewed directly on the screen. Th...") Tag: Visual edit
  • 16:32, 21 July 2022 Sean Sanders talk contribs created page Datalogging (Created page with "All of the sensors on a given module are logged at all times at 1 minute intervals. These logs can be viewed from the Datalog View page (Pg. 75) and downloaded or deleted from the Datalog Files page (Pg. 75). The files automatically roll over, and store around 1 month of data. Note: for long-term compliance logs, which are stored and downloaded elsewhere, see the article "EMD Compliance Log". === DATALOG VIEWING === The Datalog View page (Pg. 75) can be used to look at...") Tag: Visual edit
  • 16:30, 21 July 2022 Sean Sanders talk contribs created page Custom Modbus Map (Created page with "=== Background === The EIM contains the sole modbus (RS-485) connection for the entire system. However, each module's data is requested with a unique ID. Additionally, each module has a large number of registers, and for a given application only a small number are actually needed. The EIM contains the feature where a custom modbus map can be uploaded which contains a list of target registers that are reassigned a new register number, and are moved to the EIM's modbus ID...") Tag: Visual edit
  • 16:27, 21 July 2022 Sean Sanders talk contribs created page Modbus RTU (Created page with "=== Introduction === This document describes an overview of Modbus and how it is used in the ETS system. Modbus (RTU) can be used to read a variety of data from the ETS system to some sort of Modbus master device, to be used remotely or on-site. A proper understanding of how the items are addressed and scaled in ETS will help ensure your system setup works correctly. === Brief Modbus Overview === Modbus is a serial communication protocol that is designed for reading and...") Tag: Visual edit
  • 16:22, 21 July 2022 Sean Sanders talk contribs created page Engine Information (Created page with "The Engine Info screen (Pg. 7) configures and displays engine specific data. The information is available for view in Operator security mode. To edit or modify any of the data, Setup or Engineering security mode is required. Engineering mode is required to modify the engine configuration. *Engine Status – Displays the engine run signal status as either ‘Running’ or ‘Run Signal Not Detected’ based on the run signal auto-detect *Engine Hours – Displays the curr...") Tag: Visual edit
  • 16:21, 21 July 2022 Sean Sanders talk contribs created page Alarms (Created page with "The EIM and associated modules are capable of identifying a wide range possible alarm conditions. Depending on the module there are a set of custom and fixed alarms in the system to generate an alarm event for the error condition. See the “ALARMS” section of any of the modules for details on how to configure an alarm. As discussed in the module alarm sections, most alarms can be set up to close the error relay and shutdown the engine on critical alarms (other than an...") Tag: Visual edit
  • 16:20, 21 July 2022 Sean Sanders talk contribs created page Timers (Created page with "The EIM is capable of running eight (8) general purpose timers and three (3) EMD compliance timers simultaneously. Timers can be viewed, updated, or created from the Timer Management screen (Pg. 20) of the EIM. The screen can be accessed by selecting the “Timers” button in the footer of the display. A security level of Setup or Engineering is required to update or create timers. === CREATING A TIMER === To create a timer, select the any of the available “Add” bu...") Tag: Visual edit
  • 16:08, 21 July 2022 Sean Sanders talk contribs created page Panel Switch Connections (Created page with "=== Background === * Most panels wire the panel switches to the Brain module - Start, Stop, Reset, Speed Auto, Speed Manual, Speed Increase, and Speed Decrease*Insert Image Here* Normal Switch Wiring Locations * Alternately, a new revision of the DCT adds panel switch wiring to the back of the screen. This allows for less wiring between the inner door and the panel, and frees up the inputs on the Brain to be used for other purposes. <nowiki>*</nowiki>Insert Image Her...") Tag: Visual edit
  • 16:07, 21 July 2022 Sean Sanders talk contribs created page USB Format Tool (Created page with "The DCT has a USB format tool that can be used to re-format and partition a USB drive. This will help make a drive compatible with all parts of the EMIT system. Warning: Formatting a drive will erase all files previously on the drive To use the tool, perform the following steps: # Enter the Setup or Engineering password under the 'Access' Menu # Navigate to 'Settings' -> 'System / Global Settings' -> 'Format USB Drive' # Put a USB drive in the back of the touchscreen...") Tag: Visual edit
  • 16:06, 21 July 2022 Sean Sanders talk contribs created page Software Update (Created page with "The DCT can have its software updated using a USB drive. To update the software, follow these steps. * Obtain a software update from this location by selecting the latest "DCT_update..." file. Software Updates * Download the file * Insert a USB drive into the computer * Drag the file from the 'Downloads' folder into the USB drive * Eject the drive, then insert into back of screen * Enter the engineering password on the screen * Navigate to "Settings" -> "System Settings...") Tag: Visual edit
  • 16:06, 21 July 2022 Sean Sanders talk contribs created page Manual (Created page with "The DCT manual can be viewed or downloaded here: https://drive.google.com/open?id=1QyJhIHLQgWs3TdRcVmFp5m048vKKeY5V") Tag: Visual edit
  • 16:05, 21 July 2022 Sean Sanders talk contribs created page Modbus (Created page with "The latest information and register list for the DCT can be seen here: https://drive.google.com/open?id=1uZHGhsb_jMc-kCS1jnT7NDkBjcN0WOxf") Tag: Visual edit
  • 16:04, 21 July 2022 Sean Sanders talk contribs created page Panel Install Guides (Created page with "Full panel install guide, CAT3300 series: https://drive.google.com/file/d/0BzOiNHLPWdg1Nm5xd2V2QUMybzg/view?usp=sharing&resourcekey=0-BeKtdVPfXRd9FKF_h0AURg") Tag: Visual edit
  • 15:59, 21 July 2022 Sean Sanders talk contribs created page Wi-Fi Console Pages (Created page with "From the top right menu on a phone, or along the top on a computer, there will be the following page categories: Status, Compressor Master, Alerts, Engine Data Translator, Modbus Slave, and Debug. Each of these 6 pages are detailed below. ===Status=== The Status page shows the current readings for engine and compressor data. Settings cannot be edited on this page. Also shown under “General” is the serial number and software version. <nowiki>*</nowiki>Insert Images*...") Tag: Visual edit
  • 15:54, 21 July 2022 Sean Sanders talk contribs created page Config Tool (Created blank page)
  • 15:48, 21 July 2022 Sean Sanders talk contribs created page Connecting (Created page with "Check your target device’s Wi-Fi settings for a network called “EDR_xxxx”, where xxxx is the serial number of the Data Relay. Connect to this network and enter the password ‘emitemit’. Note: There will be no internet access while you are connected to the network. It is recommended that you turn auto reconnect off. Once connected, open a web browser and type <nowiki>http://172.16.16.1/</nowiki> . This will bring up the Data Relay console. <nowiki>*</nowiki>In...") Tag: Visual edit
  • 15:47, 21 July 2022 Sean Sanders talk contribs created page Troubleshooting Guide (Created page with "This document covers troubleshooting steps for various EDR issues: https://drive.google.com/file/d/1-gnsQWNj71XOUQYHcC5wN2dpd5X-1Hr6/view?usp=sharing") Tag: Visual edit
  • 15:46, 21 July 2022 Sean Sanders talk contribs created page Internal EDT Update (Created page with "The EDR has an internal EDT that is updated separately from the EDR itself. It is uncommon that it needs to be updated, but if it does follow these steps. 1. Download the latest EDT_xxxx.hex file from this page 2. Put the file on a USB drive 3. Remove the cover of the EDR by loosening the screws on one of the end caps 4. Locate the USB port near the power switch that was previously hidden <nowiki>*</nowiki>Insert Image* ''USB port location'' 5. Turn power off a...") Tag: Visual edit