Controls Tips Newsletter Archive

From EMIT Controls
Revision as of 17:12, 29 July 2022 by Thomas Peterson (talk | contribs) (Created page with "This page shows old email tips sent out on the mailing list, with the newest first. == April 8 2022 == '''Brain PID glitch resolved''' Versions 2200 and 2209 of the Brain (Annunciator) software had an issue where on rare occasion the output of a PID loop would jump to a high or low value. This was fixed in version 2305, which can be found with other updates here: [https://emittechnologies.sharepoint.com/:f:/g/EjzP5UrSAHxDraE3F2QH2k0BQf3zQZxxiSyI6cho1bxqPg Software Upd...")
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)

This page shows old email tips sent out on the mailing list, with the newest first.

April 8 2022

Brain PID glitch resolved

Versions 2200 and 2209 of the Brain (Annunciator) software had an issue where on rare occasion the output of a PID loop would jump to a high or low value. This was fixed in version 2305, which can be found with other updates here: Software Updates

Tip: Telematics config backups

Did you know that DCTs on active telematics backup the Brain config once per day? On the Connect Portal the "config" tab of a unit can be used to view when configuration items were changed. Additionally, EMIT can provide a copy of a past config if needed by emailing telematics@emittechnologies.com

Tip: Lube Rate Monitoring

On both the DCT and EIM the system can be set up to monitor the divider block lucubration rate as a percentage of the rated value. This can be set up under Annunciator/Brain - Input Setup - No Flow. The system will track the rate as a percentage: if under 100% the unit could be under-lubricating even though the alarm isn't being reached. If over 100% the unit could be wasting oil. Info on how to set up on an EIM is here, and the DCT page works the same : Annunciator Setup - No Flow Monitoring


March 23 2022

New DCT Version Released - 1.52

A new DCT version is now available here: Software Updates

Changes with this version:

  • The dual recycle loop now has a manual mode
  • No-flow monitoring can now track pints per day of oil usage
  • ECU information page shows a few new sensors
  • Remote sending of discharge temperatures now works better with alternate input names. For example, if some units on telematics are missing cylinders 1 and 3, this likely will fix the issue.


New EIM Version Released - 2.26

There is also a new EIM version available at the link above.

Changes with this version:

  • Ported blowdown to header, dual recycle, and dual speed control options from the DCT to the EIM
  • Datalog rate can now be adjusted
  • Support for the EMIT ECU added
  • Idle permissive can now use a few engine sensors as the threshold
  • Input calibration ported from DCT
  • Issue has been fixed where the CAT error code was not collected correctly for remote data. Recommend updating EDT as well to v1871 to improve pulling of error codes.
  • Remote sending of discharge temperatures now works better with alternate input names

New Data Relay Troubleshooting Guide Available

A new troubleshooting guide is available that covers common fixes for setting up a Data Relay. It can be found here EDR Troubleshooting Guide