EIM Overview: Difference between revisions

From EMIT Controls
No edit summary
No edit summary
Line 1: Line 1:
See the bottom part of this page for a general overview, or the articles below for specific topics.
==EIM Documents and Guides==
==EIM Documents and Guides==


===Main Articles===
[[EIM User Interference]]
[[EIM User Interference]]


Line 8: Line 11:


[[EIM Engine Information]]
[[EIM Engine Information]]
[[EIM Modbus RTU]]
[[EIM Custom Modbus Map]]


[[EIM Datalogging]]
[[EIM Datalogging]]
Line 20: Line 19:


[[EIM Notes Page]]
[[EIM Notes Page]]
===Minor Topics===
[[EIM Modbus RTU]]
[[EIM Custom Modbus Map]]


[[EIM Open Source Software Notice]]
[[EIM Open Source Software Notice]]
Line 34: Line 40:


== Overview ==
== Overview ==
Video available for this topic: https://www.youtube.com/watch?v=GLwC7T6rGMQ
Video available for this topic: https://www.youtube.com/watch?v=GLwC7T6rGMQ


Line 41: Line 48:


The enclosure of the EIM was designed to be installed either externally using the faceplate and the base or within a panel using only the faceplate. If mounting externally, the EIM can accommodate the mounting of any one module within the base of the enclosure.
The enclosure of the EIM was designed to be installed either externally using the faceplate and the base or within a panel using only the faceplate. If mounting externally, the EIM can accommodate the mounting of any one module within the base of the enclosure.
=== Specifications ===
'''Power'''
*12 – 30VDC power supply input range
*10 Watts maximum consumption
'''Environmental'''
*Temperature: -40°C to +65°C (-40°F to 149°F)
*Humidity: 0% - 90%, non-condensing
'''Communication'''
*Controller Area Network (CAN) network for access to additional EMIT ETS modules
*USB host for datalog access and software updates
*RS-485 half-duplex MODBUS RTU

Revision as of 17:03, 4 August 2022

See the bottom part of this page for a general overview, or the articles below for specific topics.

EIM Documents and Guides

Main Articles

EIM User Interference

EIM Timers

EIM Alarms

EIM Engine Information

EIM Datalogging

EIM System Settings or Utilities Pages

EIM Software Update

EIM Notes Page


Minor Topics

EIM Modbus RTU

EIM Custom Modbus Map

EIM Open Source Software Notice

EIM SD Or Boot Issues

EIM Ethernet

EIM Security Key

EIM Shutdown Logs

EIM Modbus Temporary Disable

Overview

Video available for this topic: https://www.youtube.com/watch?v=GLwC7T6rGMQ

The EMIT Interface Module (EIM) provides an 8” touchscreen display and communication hub for any one module, or multiple modules, connected to the Controller Area Network (CAN) of the EIM. Modules connected to the EIM will automatically populate as buttons on the System Menu screen (Pg. 0) of the display. Selecting any of the module buttons allows for direct interaction with the respective module.

Other functions not directly related to module interaction include the system run signal trigger, security passwords and access, timer management, alarms, date and time, sensor data logging, and MODBUS communications.

The enclosure of the EIM was designed to be installed either externally using the faceplate and the base or within a panel using only the faceplate. If mounting externally, the EIM can accommodate the mounting of any one module within the base of the enclosure.

Specifications

Power

  • 12 – 30VDC power supply input range
  • 10 Watts maximum consumption

Environmental

  • Temperature: -40°C to +65°C (-40°F to 149°F)
  • Humidity: 0% - 90%, non-condensing

Communication

  • Controller Area Network (CAN) network for access to additional EMIT ETS modules
  • USB host for datalog access and software updates
  • RS-485 half-duplex MODBUS RTU