All public logs
From EMIT Controls
Combined display of all available logs of EMIT Controls. You can narrow down the view by selecting a log type, the username (case-sensitive), or the affected page (also case-sensitive).
(newest | oldest) View (newer 50 | older 50) (20 | 50 | 100 | 250 | 500)- 20:52, 4 September 2024 Thomas Peterson talk contribs created page File:DetStatus1.png
- 20:52, 4 September 2024 Thomas Peterson talk contribs uploaded File:DetStatus1.png
- 20:43, 4 September 2024 Thomas Peterson talk contribs uploaded a new version of File:DetSetup.png
- 20:33, 4 September 2024 Thomas Peterson talk contribs created page File:DetSetup.png
- 20:33, 4 September 2024 Thomas Peterson talk contribs uploaded File:DetSetup.png
- 20:26, 4 September 2024 Thomas Peterson talk contribs created page File:EDT home detcon.png
- 20:26, 4 September 2024 Thomas Peterson talk contribs uploaded File:EDT home detcon.png
- 20:23, 4 September 2024 Thomas Peterson talk contribs created page Connecting Ignition to a DetCon (Created page with "==Overview== The EMIT ignition system can be linked to a MotorTech (TM) DetCon controller, and the data from the DetCon can be used to retard individual cylinder timings of the ignition. This page describes how to set up and use this feature. ==Installation== Install the DetCon as specified in the Motortech instructions. Important notes and clarifications: #The knock sensors are wired in '''firing''' order. The "Sensor 1" input on the Detcon will wire to the knock se...")
- 14:30, 27 August 2024 Thomas Peterson talk contribs created page File:Home 3.png
- 14:30, 27 August 2024 Thomas Peterson talk contribs uploaded File:Home 3.png
- 14:29, 27 August 2024 Thomas Peterson talk contribs uploaded a new version of File:Home 2.png
- 14:25, 27 August 2024 Thomas Peterson talk contribs created page File:Home 2.png
- 14:25, 27 August 2024 Thomas Peterson talk contribs uploaded File:Home 2.png
- 19:51, 15 August 2024 Thomas Peterson talk contribs created page Standby start or Unexpected start fault (Created page with "In Brain v3180 a new built-in fault was added for an unexpected engine start. This logic will trip if the rpm goes above crank terminate for more than 1/2 second while the panel is in standby. ==Logic== In a normal startup on a CAT engine, the sequence will be: #Operator presses RESET button #EMIT panel goes to STANDBY and the DRIVEN EQUIPMENT READY output turns on (goes clear) #The CAT panel can be cleared of all alarms #(If switch present and not previously set) CAT...")
- 19:47, 15 August 2024 Thomas Peterson talk contribs created page File:StandbyFault.png
- 19:47, 15 August 2024 Thomas Peterson talk contribs uploaded File:StandbyFault.png
- 21:35, 12 August 2024 Thomas Peterson talk contribs created page File:Dct wifi downloads.png
- 21:35, 12 August 2024 Thomas Peterson talk contribs uploaded File:Dct wifi downloads.png
- 21:34, 12 August 2024 Thomas Peterson talk contribs created page File:Dct wifi do.png
- 21:34, 12 August 2024 Thomas Peterson talk contribs uploaded File:Dct wifi do.png
- 21:34, 12 August 2024 Thomas Peterson talk contribs created page File:Dct wifi di.png
- 21:34, 12 August 2024 Thomas Peterson talk contribs uploaded File:Dct wifi di.png
- 21:33, 12 August 2024 Thomas Peterson talk contribs created page File:Dct wifi brain AITC.png
- 21:33, 12 August 2024 Thomas Peterson talk contribs uploaded File:Dct wifi brain AITC.png
- 16:43, 31 July 2024 Thomas Peterson talk contribs uploaded a new version of File:Restart1.png
- 18:50, 30 July 2024 Thomas Peterson talk contribs uploaded a new version of File:Test msg list.png
- 18:50, 30 July 2024 Thomas Peterson talk contribs uploaded a new version of File:Test callout1.png
- 18:49, 30 July 2024 Thomas Peterson talk contribs created page Unit Test Callouts and Data Polls (Created page with "== Overview == On the telematics portal you can send two types of test messages to a unit- request for test callout and request for immediate data send. These tests are found by selecting a unit then navigating to the "Callout Scheduling" dropdown followed by "Test Callout". File:Test callout1.png == Test Page == The test page has two test buttons and a list of messages that have been sent. File:Test msg list.png In the message list it will show a list of p...")
- 18:42, 30 July 2024 Thomas Peterson talk contribs created page File:Test callout1.png
- 18:42, 30 July 2024 Thomas Peterson talk contribs uploaded File:Test callout1.png
- 18:42, 30 July 2024 Thomas Peterson talk contribs created page File:Test msg list.png
- 18:42, 30 July 2024 Thomas Peterson talk contribs uploaded File:Test msg list.png
- 19:41, 16 July 2024 Thomas Peterson talk contribs created page File:Single Cyl Drop.png
- 19:41, 16 July 2024 Thomas Peterson talk contribs uploaded File:Single Cyl Drop.png
- 19:39, 16 July 2024 Thomas Peterson talk contribs created page File:SparkGraph.png
- 19:39, 16 July 2024 Thomas Peterson talk contribs uploaded File:SparkGraph.png
- 19:25, 16 July 2024 Thomas Peterson talk contribs uploaded a new version of File:Gov-pd-wiring.png
- 17:15, 2 July 2024 Thomas Peterson talk contribs created page EDR Troubleshooting - Engine data issues (Created page with "Symptom: There is missing engine data on the site but compressor data is working ==Verify Wiring== 1. The EDR will have wires from pin 9,10 of the module to the pink and purple wires in the CAT panel (A3 only) 2. The EDR will have wires from pin 13, 14 of the module to the green and yellow wires in the CAT panel Verify CAN termination 3. There is a CAN termination switch next to pin 14 of the EDR. If this is ON (to outside of module) then the CAT termination resistor...")
- 17:11, 2 July 2024 Thomas Peterson talk contribs created page EDR Troubleshooting - Incorrect Compressor Data (Created page with "Symptom: Some data from the compressor is showing up on the site, but some data is missing or incorrect ==Alter port timings== 1. Connect to the wifi terminal. Directions are in Appendix A. 2. In some cases, increasing some port delays can help with communications a. In the wifi terminal under the “Modbus Master” tab, open the heading “Port Timings” b. Increase the Write Delay Us to 50,000 c. Increase the Read delay Us to 4,000 ==Check Base Configuration==...")
- 17:10, 2 July 2024 Thomas Peterson talk contribs created page EDR Troubleshooting - Incorrect callout descriptions (Created page with "Symptom: Callouts are being sent normally but the description is not correct '''Verify Fault Code Table''' 1. Connect to the EDR wifi console. Instructions can be found here: EDR Wi-Fi Console 2. Go to the “Alerts” tab of the console 3. Open the “Shutdown Code” table 4. Edit the table to match the panel a. For TTD or DD40, this table should match the shutdown legend exactly b. For a DE3000, this table will match the channel list c. For a centurion, th...")
- 17:06, 2 July 2024 Thomas Peterson talk contribs created page EDR Troubleshooting - Missing Compressor Data (Created page with "Symptom: On the Connect site there is no compressor data (e.g. Annunciator Run Code, Suction Pressure, etc.), or on the Wifi console there are expected data items with a timeout of “Never”. ==Note that some values may not be present== 1. For a TTD or DD40, there won’t be any process pressures or temperatures (though there can be temperatures if a TDXM or DSM are set up). The Run Status and Fault Code should still show up though. ==Check EDR Port Setup== 2. Unde...")
- 16:46, 2 July 2024 Thomas Peterson talk contribs created page File:Comm timeout.png
- 16:46, 2 July 2024 Thomas Peterson talk contribs uploaded File:Comm timeout.png
- 14:08, 20 June 2024 Thomas Peterson talk contribs created page File:Edr test Sw.jpg
- 14:08, 20 June 2024 Thomas Peterson talk contribs uploaded File:Edr test Sw.jpg
- 14:02, 20 June 2024 Thomas Peterson talk contribs created page File:Dct test sw.jpg
- 14:02, 20 June 2024 Thomas Peterson talk contribs uploaded File:Dct test sw.jpg
- 22:06, 19 June 2024 Thomas Peterson talk contribs created page Checking for Test Software (Created page with "If a module has manufacturing test software installed or test mode active, it won't work normally. This page shows how to verify if normal software is installed. '''AFRC''' If the hardware ID ends in a "1", it is test software. If it ends in another number, it is normal software. '''DCT''' The DCT boots to a test mode if an internal switch is in a specific setting. To get it out of test mode, remove the back cover and switch the 4pin dip switch to all OFF. '''EDR'''...")
- 21:13, 11 June 2024 Thomas Peterson talk contribs created page File:Callout summary.png
- 21:13, 11 June 2024 Thomas Peterson talk contribs uploaded File:Callout summary.png