User contributions for Thomas Peterson
From EMIT Controls
31 January 2024
- 17:3717:37, 31 January 2024 diff hist +1,940 Vibration Overview No edit summary
- 17:3617:36, 31 January 2024 diff hist +4 N Vibration Overview Created page with "asdf" Tag: Visual edit
- 17:3517:35, 31 January 2024 diff hist +39 MediaWiki:Sidebar No edit summary current
29 January 2024
- 23:0123:01, 29 January 2024 diff hist +1,084 Dual Recycle Setup No edit summary current
- 17:1217:12, 29 January 2024 diff hist +154 Downtime Type No edit summary current
26 January 2024
17 January 2024
- 17:0517:05, 17 January 2024 diff hist 0 Spare Parts Reference →External Actuators and Related
- 17:0417:04, 17 January 2024 diff hist +64 Spare Parts Reference →External Actuators and Related
5 January 2024
- 21:2521:25, 5 January 2024 diff hist +1,414 N EDR Loopback Test Created page with "A loopback test involves setting up the EDR to communicate from its own master to slave port. This tests that both ports are functional. ==Test Instructions== * Disconnect any wires in the EDR pins 3-8 and set aside. (We recommend taping over the wires so they don't short to anything) * With two spare short wires, connect 4-7 and 5-8 600px * Connect to the EDR wifi (See here for instructions) * On the "Modbus Mas..." current
- 21:1921:19, 5 January 2024 diff hist 0 N File:Loopback.png No edit summary current
- 21:1721:17, 5 January 2024 diff hist +23 EDR Overview →Minor Topics current
15 December 2023
- 22:4722:47, 15 December 2023 diff hist +6 EDR to 20240 Connection →Background current
- 19:5819:58, 15 December 2023 diff hist +22 EDR to 20240 Connection →Wiring
- 19:5719:57, 15 December 2023 diff hist 0 File:Edr emd.png Thomas Peterson uploaded a new version of File:Edr emd.png current
- 19:5519:55, 15 December 2023 diff hist 0 N File:Edr emd.png No edit summary
- 18:3118:31, 15 December 2023 diff hist +290 EDR to 20240 Connection →Scaling
- 18:2118:21, 15 December 2023 diff hist +972 EDR to 20240 Connection No edit summary
- 18:1318:13, 15 December 2023 diff hist +1,452 N 20240 EMD Modbus Table Created page with "{| class="wikitable" |+ |- ! Register !! Description !! Pin(s) !! Offset !! Scale |- | 30001 || Thermocouple 1 Reading || 24-25 || -273 || 0.03125 |- | 30002 || Thermocouple 2 Reading || 26-27 || -273 || 0.03125 |- | 30003 || Thermocouple 3 Reading || 28-29 || -273 || 0.03125 |- | 30004 || Thermocouple 4 Reading || 30-31 || -273 || 0.03125 |- | 30005 || Thermocouple 5 Reading || 32-33 || -273 || 0.03125 |- | 30006 || Thermocouple 6 Reading || 34-35 || -273 || 0.03125 |..." current
- 18:1118:11, 15 December 2023 diff hist +28 Other Topics No edit summary
- 18:0618:06, 15 December 2023 diff hist −19 EDR to 20240 Connection →Input Numbering
- 18:0418:04, 15 December 2023 diff hist +49 EDR to 20240 Connection →Input Numbering
- 18:0418:04, 15 December 2023 diff hist +1,683 EDR to 20240 Connection →Wiring
- 17:5917:59, 15 December 2023 diff hist 0 N File:Emd therm resistor.png No edit summary current
- 17:5117:51, 15 December 2023 diff hist +1 EDR to 20240 Connection No edit summary
- 17:5117:51, 15 December 2023 diff hist +252 EDR to 20240 Connection No edit summary
- 17:3917:39, 15 December 2023 diff hist +365 N EDR to 20240 Connection Created page with "== Background == The 20240 (EMD) is a module that historically is used for ZZZZ compliance monitoring. Since it has a RS-485 slave port, it can also be used as a generic sensor to modbus translator. In a typical scenario, a 20240 and a few sensors could be added to an old annunciator panel (e.g. TTD or DD-40) to allow the EDR to send the sensor values remotely."
- 17:3617:36, 15 December 2023 diff hist +29 EDR Overview →Minor Topics
21 November 2023
- 17:3517:35, 21 November 2023 diff hist +2,396 Blowdown With Recycle Sequence →Sequence Setup current
- 17:3417:34, 21 November 2023 diff hist +1,095 N Blowdown With Recycle Sequence Created page with "==Overview== The Dynamic Control panels have three options related to relieving pressure on a unit: #Blowdown vent, with a simple vent, usually to atmosphere or combuster #Blowdown to header with recycle, where suction and recycle valves are used to relieve to header #Off skid bypass, where an off-skid on/off valve is used to relieve pressure to the header This article covers option (2). ==Setting Up Valves== Before enabling this option, the valve(s) must be configu..."
- 17:3317:33, 21 November 2023 diff hist 0 N File:Blowdown recycle.png No edit summary current
- 17:2817:28, 21 November 2023 diff hist +36 Brain or Annunciator Overview →Other Topics
- 17:2817:28, 21 November 2023 diff hist +65 Annunciator Blowdown Setup No edit summary current
- 17:1117:11, 21 November 2023 diff hist +557 Troubleshooting →Engine shuts down on fault “DI-27 ADEM RUN STATUS”, even though the ADEM doesn’t show a fault code current
- 16:5216:52, 21 November 2023 diff hist +174 Panel to ADEM(r) Interfacing →Overview
- 16:5116:51, 21 November 2023 diff hist +16 MediaWiki:Sidebar No edit summary
- 16:5016:50, 21 November 2023 diff hist +19 MediaWiki:Sidebar No edit summary
- 16:4716:47, 21 November 2023 diff hist +7 Troubleshooting →Startup fails with “ECU fails to start” but the unit never tries to start (CAT engines)
- 16:4616:46, 21 November 2023 diff hist +4 Troubleshooting →Startup fails with “ECU fails to start” but the unit never tries to start (CAT engines)
- 16:4616:46, 21 November 2023 diff hist −2 Troubleshooting →Startup fails with “ECU fails to start” but the unit never tries to start (CAT engines)
- 16:4516:45, 21 November 2023 diff hist +252 Troubleshooting →Engine shuts down on fault normally, but manual stop causes the shutdown to get stuck
- 16:4416:44, 21 November 2023 diff hist +519 Troubleshooting →Startup fails with “ECU fails to start” but the unit never tries to start (CAT engines)
- 16:4216:42, 21 November 2023 diff hist +837 Panel to ADEM(r) Interfacing →Start / Stop / Fault Control
- 16:4116:41, 21 November 2023 diff hist +3,176 Troubleshooting →Startup fails with “ECU fails to start” but the unit never tries to start (CAT engines)
- 15:5915:59, 21 November 2023 diff hist +1,090 Troubleshooting →Startup fails with “ECU fails to start” but the unit never tries to start (CAT engines)
- 15:5115:51, 21 November 2023 diff hist +1,333 Troubleshooting →Control Issues
- 15:3715:37, 21 November 2023 diff hist +2,834 Troubleshooting →Control Issues
16 November 2023
- 15:3115:31, 16 November 2023 diff hist +129 N Vibration Sensor Manual Created page with "The vibration sensor manual can be found here: https://drive.google.com/file/d/1GtnchWYcN2z88KCwxIXc63ATjVz1AwDg/view?usp=sharing" current
- 15:3015:30, 16 November 2023 diff hist +29 Other Topics No edit summary
9 November 2023
- 21:1121:11, 9 November 2023 diff hist +22 EDR Installation Guide No edit summary current
- 21:1121:11, 9 November 2023 diff hist 0 EDR Installation Guide No edit summary