All public logs
From EMIT Controls
Combined display of all available logs of EMIT Controls. You can narrow down the view by selecting a log type, the username (case-sensitive), or the affected page (also case-sensitive).
(newest | oldest) View (newer 50 | older 50) (20 | 50 | 100 | 250 | 500)- 22:24, 5 August 2022 Thomas Peterson talk contribs moved page File:EIM Engine Info.jpg to File:DCT Engine Info.jpg without leaving a redirect
- 22:24, 5 August 2022 Thomas Peterson talk contribs deleted page File:Creating A Timer.jpg
- 22:24, 5 August 2022 Thomas Peterson talk contribs deleted page File:Individual Shutdown Log.jpg
- 22:23, 5 August 2022 Thomas Peterson talk contribs deleted page File:Software Update.jpg
- 22:23, 5 August 2022 Thomas Peterson talk contribs deleted page File:Engine Off Diagnostic.jpg
- 22:22, 5 August 2022 Thomas Peterson talk contribs deleted page File:Load Advance.jpg
- 22:19, 5 August 2022 Thomas Peterson talk contribs deleted page File:Eim-sd-logs.png
- 22:19, 5 August 2022 Thomas Peterson talk contribs deleted page File:Datalog Viewing.jpg
- 22:19, 5 August 2022 Thomas Peterson talk contribs deleted page File:EIM Datalogging.jpg
- 22:19, 5 August 2022 Thomas Peterson talk contribs deleted page File:Digital Out Test.jpg
- 22:18, 5 August 2022 Thomas Peterson talk contribs deleted page File:System Settings.jpg
- 22:18, 5 August 2022 Thomas Peterson talk contribs deleted page File:Settings Page.jpg
- 22:17, 5 August 2022 Thomas Peterson talk contribs created page Annunciator Miscellaneous Settings (Created page with "There are some settings for the Brain that do not fit in another section so are put under Setup -> Brain -> Misc. Settings. The settings and their purpose are shown below {| class="wikitable" style="margin:auto" |+ |- ! Setting !! Description |- | Scrubber Debounce (s) || This setting gives a special debounce time for digital inputs that are used for scrubber levels. For example, if set to 3 seconds then the input will have to be faulted for 3 full seconds before shutt...")
- 22:05, 5 August 2022 Thomas Peterson talk contribs created page Annunciator Cooldown Mode (Created page with "The Brain has a manual cooldown mode that is accessed on the Cooldown Mode screen. This screen is reached from the main Brain setup menu button “Cooldown Mode”. On this page, select “Start Cooldown” to start a 5-minute cooldown timer. While this timer is active, the process pressure (Suction and discharge stages) will be changed to a ‘warning’ so that the compressor can be unloaded. File:Cooldown-mode.png")
- 22:05, 5 August 2022 Thomas Peterson talk contribs created page File:Cooldown-mode.png
- 22:05, 5 August 2022 Thomas Peterson talk contribs uploaded File:Cooldown-mode.png
- 21:58, 5 August 2022 Thomas Peterson talk contribs moved page Annunciator Digital Out Test Screen to Annunciator Output Testing without leaving a redirect
- 21:28, 5 August 2022 Thomas Peterson talk contribs created page File:Adem-can-term.jpg
- 21:28, 5 August 2022 Thomas Peterson talk contribs uploaded File:Adem-can-term.jpg
- 20:05, 5 August 2022 Thomas Peterson talk contribs created page Panel to ADEM(r) Interfacing (Created page with "==Overview== On various Caterpillar engines, the ADEM(r) system is used to control the engine operation, and the EMIT Brain (Annunciator) is used to monitor and protect the compressor (which falls under the CAT category “Driven Equipment”). In some cases, the ADEM is generically called an ECU (Engine Control Unit). Similar to other ECUs (E.g. older CAT EIS, or Waukesha ESM) the ADEM features a number of connections that are used by the panel to control engine operat...")
- 17:25, 5 August 2022 Thomas Peterson talk contribs created page DCT Local Wifi (Created page with "==Overview== The Dynamic Control Touchscreen (DCT) features a local Wifi connection that can be connected to with a phone to view current runtime information. This allows viewing sensor data from around the site. ==How to Connect== #On your phone, check under WiFi connections for an access point named “EMIT_XXXX”, where XXXX is the serial number of the touchscreen. #Select the connection, and for the password enter “emitemit” (all lowercase). It is recommende...")
- 17:25, 5 August 2022 Thomas Peterson talk contribs created page File:Dct-wifi.png
- 17:25, 5 August 2022 Thomas Peterson talk contribs uploaded File:Dct-wifi.png
- 17:23, 5 August 2022 Thomas Peterson talk contribs created page Adding Engine Failure Status (Created page with "==Overview== Currently, most panels use the “Engine running” signal from the CAT(r) panel to determine if the engine is running. It goes to DI-27 as a B1 or B2 digital input, and is used for some minor other logic. CAT(r) has another signal, “Engine failure” that can be added to another digital input as an ‘A’ shutdown. This will prevent the annunciator from entering the start sequence if the CAT(r) panel is faulted (even though the engine would not start i...")
- 17:16, 5 August 2022 Thomas Peterson talk contribs created page Miscellaneous Start Permissive (Created page with "==Overview== The Brain (annunciator) has the ability to add a generic start permissive which specifies a sensor condition must be met before the start sequence will commence. After the unit is running, the permissive no longer needs to be met until the next startup. '''Requirements''' #The Brain (annunciator) should be updated to 1303 or newer #The DCT should be updated to 1.19.109 or newer OR the EIM should be updated to 2.21.63 or newer #The sensor needed for the pe...")
- 17:16, 5 August 2022 Thomas Peterson talk contribs created page File:Misc-permissive.png
- 17:16, 5 August 2022 Thomas Peterson talk contribs uploaded File:Misc-permissive.png
- 17:05, 5 August 2022 Thomas Peterson talk contribs created page Annunciator Input Calibration (Created page with "==Overview== In most cases, Brain (annunciator) inputs should not need to be calibrated. Calibration may be needed though for very high precision operations or if physical factors affect sensor readings. With DCT version 1.35.113 and annunciator version 1639 (or higher) thermocouple and analog inputs can be calibrated. ==Calibration Setup Screen== After entering Engineering Access level, Navigate to Settings -> Brain -> Inputs Setup -> Input Calibration to access the...")
- 17:04, 5 August 2022 Thomas Peterson talk contribs created page File:Ann-input-cal.png
- 17:04, 5 August 2022 Thomas Peterson talk contribs uploaded File:Ann-input-cal.png
- 16:51, 5 August 2022 Thomas Peterson talk contribs created page File:Exp2-example.png
- 16:51, 5 August 2022 Thomas Peterson talk contribs uploaded File:Exp2-example.png
- 16:39, 5 August 2022 Thomas Peterson talk contribs created page File:Bypass-multi-status.png
- 16:39, 5 August 2022 Thomas Peterson talk contribs uploaded File:Bypass-multi-status.png
- 16:38, 5 August 2022 Thomas Peterson talk contribs created page File:Multi-bypass-setup.png
- 16:38, 5 August 2022 Thomas Peterson talk contribs uploaded File:Multi-bypass-setup.png
- 16:31, 5 August 2022 Thomas Peterson talk contribs created page Annunciator Bypass Setup (Created page with "==Overview== A unit can be configured to have one or more bypass (on / off bypass) valves that are automatically actuated by the system. Note that this is different from proportional recycle valves which can gradually recycle gas. For those types of valves see Dual Recycle Setup. ==Basic Bypass Setup== To assign an output (and optionally feedback inputs) to use a normal Bypass valve, see Annunciator Valve Setup which talks about the output to valve assignmen...")
- 16:25, 5 August 2022 Thomas Peterson talk contribs created page File:Bypass-setup1.png
- 16:25, 5 August 2022 Thomas Peterson talk contribs uploaded File:Bypass-setup1.png
- 15:58, 5 August 2022 Thomas Peterson talk contribs created page File:Di-loop.png
- 15:58, 5 August 2022 Thomas Peterson talk contribs uploaded File:Di-loop.png
- 15:53, 5 August 2022 Thomas Peterson talk contribs created page File:Di-detect.PNG
- 15:53, 5 August 2022 Thomas Peterson talk contribs uploaded File:Di-detect.PNG
- 15:25, 5 August 2022 Thomas Peterson talk contribs created page Digital Inputs Detect Loop (Created page with "==Overview== The digital inputs to the Brain are most commonly connected to switches that either close or open on fault. Of the two options, normally-closed setup (where closed to ground is clear and open is faulted) is more safe because a wire breakage will show as faulted. However, there can also be cases where a wire is somewhere shorted to ground on the skid and the input will always read grounded even when the switch opens. To help avoid this scenario, some versio...")
- 14:39, 5 August 2022 Thomas Peterson talk contribs deleted page User Interference (content was: "#REDIRECT EIM User Interference", and the only contributor was "Sean Sanders" (talk))
- 14:39, 5 August 2022 Thomas Peterson talk contribs deleted page Timers (content was: "#REDIRECT EIM Timers", and the only contributor was "Sean Sanders" (talk))
- 14:39, 5 August 2022 Thomas Peterson talk contribs deleted page Throttle Calibration (content was: "#REDIRECT Speed Throttle Calibration", and the only contributor was "Sean Sanders" (talk))
- 14:39, 5 August 2022 Thomas Peterson talk contribs deleted page System Settings or Utilities Pages (content was: "#REDIRECT EIM System Settings or Utilities Pages", and the only contributor was "Sean Sanders" (talk))
- 14:38, 5 August 2022 Thomas Peterson talk contribs deleted page EIM Shutdown Logs (content was: "Beginning with EIM version 1.94, the EIM will save a log of sensor data for the previous 10 shutdowns, whether the shutdown was a fault or not. As new shutdowns occur, the oldest logs will be deleted so that there are never more than 10 logs. These logs can be viewed, graphed, and downloaded (to view in Excel (R) ) just the same as the normal alarm logs are. However, there are two benefits of these logs over normal alarm logs: * Sometimes a unit will be reset (and the alarm l...")
- 14:38, 5 August 2022 Thomas Peterson talk contribs deleted page Shutdown Logs (content was: "#REDIRECT EIM Shutdown Logs", and the only contributor was "Sean Sanders" (talk))