User contributions for Sean Sanders

From EMIT Controls
Search for contributionsExpandCollapse
⧼contribs-top⧽
⧼contribs-date⧽

(newest | oldest) View ( | ) (20 | 50 | 100 | 250 | 500)

26 July 2022

21 July 2022

  • 22:5422:54, 21 July 2022 diff hist +2,024 N Annunciator Purge SetupCreated page with "The annunciator Purge / Blowdown setup screen is used to set up two features: # Low Purge Alarm # High blowdown limit / alarm The setup page is shown below. To reach this page, while in "Engineering" access mode navigate to "Annunciator Setup" -> "Outputs Setup" -> "Purge / Blowdown Limits". Note that neither of these functions will work if autostart or an ECU is not used. <nowiki>*</nowiki>Insert Image* === Annunciator Purge / Blowdown Alarm Setup === ← Controls..." Tag: Visual edit
  • 22:5322:53, 21 July 2022 diff hist +1,161 N Annunciator Setup - ECU SelectionCreated page with "The “Output Scheme” specifies the general way the annunciator outputs are integrated into the engine. The annunciator can either control the starter and ignition directly, or can be configured to control through an external ECU: either a Caterpillar ADEM or a Waukesha ESM. The Output Scheme Setup page can be accessed from the main annunciator setup either through “ECU Integration” or through “Outputs Setup” through “Output Scheme”. <nowiki>*</nowiki>Ins..." Tag: Visual edit
  • 22:5222:52, 21 July 2022 diff hist +970 N Annunciator Setup - Prelube & PostlubeCreated page with "A Pre/Post lubrication system can be driven from the annunciator by enabling it through the Pre/Post Lube Setup Page (Pg. 672). This page can be accessed through the setup wizard, or from the main annunciator setup by selecting “Outputs Setup”, then “Pre/Post Lube Setup”. On the Pre/Postlube setup page, the Prelube and Postlube time can be specified. These are the times that the lube output (digital out 1) will run before starting the engine and after it shuts d..." Tag: Visual edit
  • 22:5122:51, 21 July 2022 diff hist +746 N Annunciator Setup - Class B & C TimersCreated page with "The length of the B and global C timer can be adjusted on the Class B/C Timer Setup Page (Pg. 634). This page can be found under "Timers Setup" -> "Class B/C Timer Lengths". Both B timers will count down from any RESET button press, and when they reach zero will arm the inputs of that class. Generally the B2 timer should be the shorter timer, intended for items that should clear during the very initial startup of the engine. The maximum C time can be optionally entered..." Tag: Visual edit
  • 22:5122:51, 21 July 2022 diff hist +773 N Annunciator Fault & Output Status ScreenCreated page with "The Annunciator Fault / Output Status Screen, in version 1.96 of the EIM, replaces an earlier version of the screen. This screen is accessed by selecting the left box on the Annunciator Home page. <nowiki>*</nowiki>Insert Image* The status categories on the left of the screen can be selected to change between views on the right side of the screen. Options are: * Faults: Shows which inputs are currently faulted * Timers: Shows status of various timers, including the..." Tag: Visual edit
  • 22:4922:49, 21 July 2022 diff hist +4 Brain or Annunciator Overview→‎Brain Documents and Guides
  • 22:4822:48, 21 July 2022 diff hist −3,450 EIM Overview→‎System Settings / Utilities Pages Tag: Visual edit

(newest | oldest) View ( | ) (20 | 50 | 100 | 250 | 500)