All public logs
From EMIT Controls
Combined display of all available logs of EMIT Controls. You can narrow down the view by selecting a log type, the username (case-sensitive), or the affected page (also case-sensitive).
(newest | oldest) View (newer 50 | older 50) (20 | 50 | 100 | 250 | 500)- 22:51, 21 July 2022 Sean Sanders talk contribs created page Annunciator Fault & Output Status Screen (Created page with "The Annunciator Fault / Output Status Screen, in version 1.96 of the EIM, replaces an earlier version of the screen. This screen is accessed by selecting the left box on the Annunciator Home page. <nowiki>*</nowiki>Insert Image* The status categories on the left of the screen can be selected to change between views on the right side of the screen. Options are: * Faults: Shows which inputs are currently faulted * Timers: Shows status of various timers, including the...") Tag: Visual edit
- 22:47, 21 July 2022 Sean Sanders talk contribs created page System Settings or Utilities Pages (Created page with " === System Settings / Utilities Pages === The "System Settings / Utilities" Page, accessed from the EIM home screen, contains several back pages for system settings. A description of each is below, or a reference to another article if it exists. <nowiki>*</nowiki>Insert Image* === About === The About screen (Pg. 4) displays the serial number, hardware version, and software version of the EIM and each module connected to the EIM. ==== Touchscreen Calibration ==== The...") Tag: Visual edit
- 21:55, 21 July 2022 Sean Sanders talk contribs created page Policies (Created page with "=== Terms of Service === The terms of service can be found here https://www.termsfeed.com/terms-conditions/c44db7644b3ee7582c41824aaaccc077 === Privacy Policy === The privacy policy can be found here https://www.termsfeed.com/privacy-policy/a137d4422f2f054c04f2a34610316d3a === App Privacy Policy === The privacy policy for the phone app can be found here: https://www.termsfeed.com/live/ea9204cb-f80a-4ea7-80ef-15d2d7011398") Tag: Visual edit
- 21:54, 21 July 2022 Sean Sanders talk contribs created page Changing a Device (Created page with "All data on the server is stored tied to a specific Unit, which is a virtual category for the data. Separately a device (DCT or EDR) is tied to that unit so that incoming data can be routed. If a device is changed (e.g. a screen breaks) inform EMIT of the unit number, old s/n, and new s/n to telematics@emittechnologies.com . We will switch the device associated with the unit, which will allow all the old callout settings and data to stay intact.") Tag: Visual edit
- 21:53, 21 July 2022 Sean Sanders talk contribs created page DCT Telematics Setup and Screens (Created page with "The DCT has several screens related to Telematics setup and status, detailed below. === Signal === Hitting the bottom left button of any screen brings up the connection status information screen. The cell or satellite status is in the bottom-right. <nowiki>*</nowiki>Insert Images* If the DCT is connected to a tower the connection information and signal strength will be shown. If there is no connection it could be because of a weak signal where a directional antenna is...") Tag: Visual edit
- 21:40, 21 July 2022 Sean Sanders talk contribs created page Dynamic Speed De-Rate (Created page with "=== Overview === A new feature with DCT version 1.55.59 and Brain version 2396 is the dynamic speed de-rate, which allows to specify a sensor condition that will clamp the top speed of the unit to some value. This can be used, for example, to lower the top speed when the intake temp is too high and speed back up again when back low. === Setup === The feature is set up at Settings - Brain - Outputs Setup - Dynamic Speed De-Rate. <nowiki>*</nowiki>Insert Image*...") Tag: Visual edit
- 21:38, 21 July 2022 Sean Sanders talk contribs created page Proportional Control Loops (Created page with "=== Overview === Starting with software version 1.38 on the DCT and 1732 on the Brain, the system features three proportional control loops that can be used for simple analog out controls from an input condition. These are similar to PID loops but cut out some unneeded options. These loops are useful for simpler and slow-moving control outputs such as a cooler louver. === Setup === Setup for a proportional control loop is found at Settings -> Brain -> Outputs Setup ->...") Tag: Visual edit
- 21:37, 21 July 2022 Sean Sanders talk contribs created page ECU Run Signal Debugging (Created page with "=== CAT->Brain (Annunciator) interface === The CAT panel has one return signal to tell the annunciator that the engine is running. On Panel schematics, this is called “ADEM RUN SIGNAL”, and closes a relay to ground. The contact of the relay is wired to digital input 27, which is automatically filled in as a normal digital input called “ADEM RUN STATUS”. The coil side of the relay is wired to two terminal blocks. On most ADEM systems, the run signal is ground dur...") Tag: Visual edit
- 21:36, 21 July 2022 Sean Sanders talk contribs created page Annunciator Setup - Buzzer (Created page with "=== Buzzer Setup === The annunciator buzzer (or siren) output has several built in functions- it will sound before autostart, auto-restart, or auto blowdown, for example. Additionally, the user can configure the buzzer to sound when certain inputs are faulted. This can be done on the "Annunciator Setup" -> "Display Setup" -> "Siren" page. <nowiki>*</nowiki>Insert Image* ''Buzzer Setup Page'' Any Digital, Analog, or Thermocouple input can be selected to cause the buzz...") Tag: Visual edit
- 21:29, 21 July 2022 Sean Sanders talk contribs created page Annunciator Dual Sensor Differential Inputs (Created page with "The annunciator has the ability to use two analog inputs to calculate a differential value on a third input. For example, this setup might be used: * AI-1: Discharge Pre-Filter, 0-100 PSI * AI-2: Discharge Post-Filter, 0-100 PSI * AI-3: Discharge filter differential, -100 - 100 PSI In this scenario, AI-1 and AI-2 would both be connected to the pressure sensors. AI-3 would not be physically connected to anything, but would calculate the differential value for display, a...") Tag: Visual edit
- 21:28, 21 July 2022 Sean Sanders talk contribs created page Annunciator Load Delay (Created page with "The annunciator can be configured to enter a load delay after startup. If an 'idle hold' (Warmup) condition is configured, the load delay will begin counting down as soon as the idle hold permissive is met. Otherwise, the load delay will count down when the unit enters full running state. The load delay timer can be setup under "Annunciator Setup"->"Timers Setup"->"Load Delay Timer". <nowiki>*</nowiki>Insert Image* If a load delay is desired, enter the number of seco...") Tag: Visual edit
- 21:27, 21 July 2022 Sean Sanders talk contribs created page Annunciator Screw Compressor Loading (Created page with "=== Overview === A screw compressor is a type of compressor that uses rotating 'screws' that continuously rotate and force air from larger to smaller air pockets. A capacity (or load) slide valve controls how much air is bypassed around the compressor, thus directly controlling load. Some compressors also have a "Vi" slider, which controls the ratio of air volume in the compressor from beginning to end of the load cycle. The annunciator can control the capacity slider, a...") Tag: Visual edit
- 21:25, 21 July 2022 Sean Sanders talk contribs created page Annunciator Digital Out Test Screen (Created page with "=== Overview === The annunciator digital out test screen is used to test the digital outputs (especially during install). The screen is reached from the annunciator home page by selecting "Annunciator Setup" -> "Annunciator Output Status / Testing" -> "Digital Out Testing" <nowiki>*</nowiki>Insert Image* To use this page, the annunciator must be in a stopped state. Select "Force ON" or "Force OFF" to force an output to that level for testing. Select "Clear Test / Do...") Tag: Visual edit
- 21:22, 21 July 2022 Sean Sanders talk contribs created page Annunciator Digital Output Selection (Created page with "The annunciator digital output selection screen can be used to assign functions to the digital outputs. This page is shown below. <nowiki>*</nowiki>Insert Image* In most cases, the setup screen for a particular function will already have a box to select an output (For example, see "Idle Hold Setup" under the speed control help). However, for some functions, the only way to assign the output is through this screen. Also, it might be desirable to have two outputs have...") Tag: Visual edit
- 21:20, 21 July 2022 Sean Sanders talk contribs created page Annunciator Wiring Diagram (Created page with "<nowiki>*</nowiki>Insert Image*") Tag: Visual edit
- 21:19, 21 July 2022 Sean Sanders talk contribs created page Annunciator Expansion Module (Created page with "=== OVERVIEW === The annunciator expansion module is an additional module available from EMIT that expands the amount of inputs and outputs available for the annunciator. The expansion module adds 12 thermocouples, 8 analog inputs, 6 digital outputs, and 2 analog outputs. === CONFIGURING EXPANSION I/O === If the expansion module is present on the communications bus along with an annunciator, there will still be only one icon on the EIM home screen for the annunciator. U...") Tag: Visual edit
- 21:17, 21 July 2022 Sean Sanders talk contribs created page Annunciator Testing Mode (Created page with "The annunciator can be used in a test mode with or without the engine running using the Annunciator Testing Mode screen (Pg. 662). This page is accessed from the annunciator main setup by selecting “Testing Mode”. <nowiki>*</nowiki>Insert Image* ''Annunciator Test Mode Page'' On the page the testing mode can be started or stopped. When started, the test mode will run for 15 minutes, or until it is stopped. During testing mode the annunciator will not shut down th...") Tag: Visual edit
- 21:16, 21 July 2022 Sean Sanders talk contribs created page Annunciator Rod Load Monitoring (Created page with "The Compressor Geometry / Performance Status screen (Pg. 683) can be used to see the current and historical values of the rod loads and compression ratios, if the compressor geometry was configured. This page is accessed from the main annunciator setup by selecting “Inputs Status” followed by “Compressor Geometry / Performance”. <nowiki>*</nowiki>Insert Image* ''Compressor Geometry / Performance Status'' The left side of the screen shows the rod load status,...") Tag: Visual edit
- 21:15, 21 July 2022 Sean Sanders talk contribs created page Annunciator No Flow Status (Created page with "The status of the no flow inputs is available on the No-Flow Input Status screen (Pg. 615). This page is reached from the main annunciator setup by selecting “Inputs Status” followed by “No-Flow Monitoring”. The no flow inputs should have been previously set up, which is covered in the article "Annunciator Setup- No Flow Monitoring". <nowiki>*</nowiki>Insert Image* ''No-Flow Status Page'' The no-flow input of interest can be selected at the top of the screen....") Tag: Visual edit
- 21:14, 21 July 2022 Sean Sanders talk contribs created page Annunciator Fault Event (Created page with "When an input faults the annunciator will shut down the engine and move to “Faulted” state and the EIM will generate an alarm event. On the annunciator home screen, the state will show as faulted and the input that faulted will be listed. Selecting the status box, or selecting the alarm event on the alarms screen, will bring up the alarm event. The alarm event will list the faulted input and show the previous 60 seconds of sensor data for the faulted sensor as a grap...") Tag: Visual edit
- 21:11, 21 July 2022 Sean Sanders talk contribs created page Annunciator Setup - Home Page Gauges (Created page with "The gauges on the annunciator home screen can be changed to show the most relevant sensors. Up to six gauges can be shown at a time, and up to five “sets” of gauges can be enabled, which causes a “Next” and “Prev” button to appear above the gauges to cycle between sets. To change the gauges shown, the Home Page Gauge Selection page (Pg. 632) is used, which is reached from the main annunciator setup by selecting “Display Setup” then “Select Home Page Gau...") Tag: Visual edit
- 21:10, 21 July 2022 Sean Sanders talk contribs created page Annunciator Setup - Custom Digital Out (Created page with "The annunciator has the ability to turn the digital outputs on and off based on a user-defined sensor condition. Any digital out that is not in use by another function can have a custom function associated with it. The custom digital out function is configured by selecting "Annunciator Setup", "Outputs Setup", then "Custom Digital Outs". <nowiki>*</nowiki>Insert Image* ''Custom Digital Output Setup'' Select the top button of the page to select an output to configure...") Tag: Visual edit
- 21:07, 21 July 2022 Sean Sanders talk contribs created page Annunciator Setup - Input Voltage Alarm (Created page with "An alarm can be defined to activate when the input voltage of the annunciator is above or below a certain value. To configure, navigate to "Annunciator Setup", "Input Setup", followed by "Input Voltage". On this page the following options are defined for the input voltage alarm. * Alarm when below: Enter a minimum voltage for the alarm, or 0 for unused * Alarm when above: Enter a maximum voltage for the alarm, or 0 for unused * Duration: Enter the alarm duration before...") Tag: Visual edit
- 21:06, 21 July 2022 Sean Sanders talk contribs created page Annunciator Setup - Custom PID (Created page with "The annunciator supports up to two custom PID analog outputs. These outputs can be used to control a variety of processes and controls. A PID output can be configured on the PID Setup Screen (Pg. 674) by navigating from the main annunciator setup to “Outputs Setup” then “Custom PID”. Note: Only experienced personnel should adjust PID settings <nowiki>*</nowiki>Insert Image* ''PID Setup Screen'' To configure a PID output, select one of the two available PID l...") Tag: Visual edit
- 21:01, 21 July 2022 Sean Sanders talk contribs created page Annunciator Setup - Speed Control (Created page with "If an EMIT speed controller is not used on the engine, the annunciator can control speed through an analog output connected to the ECU or another governor that uses an analog input to control the speed setpoint. Whether or not the speed output is used, an idle permissive condition can also be added to control a digital output to hold the engine at idle. Either page is accessed from the main annunciator setup by selecting “Outputs Setup” followed by “Speed Control O...") Tag: Visual edit
- 20:59, 21 July 2022 Sean Sanders talk contribs created page Annunciator Setup - Autostart (Created page with "If using EMIT engine controls, the annunciator can be used to autostart the engine. During autostart, the annunciator will actuate the STARTER output (digital out 2) and activate the fuel valve, and crank until the engine reaches a cutoff speed. The annunciator will then communicate with the (EMIT) Governor to idle for a specified amount of time, then ramp to the Auto governor operating condition. If not using an EMIT governor, the autostart function cannot be used, but...") Tag: Visual edit
- 20:57, 21 July 2022 Sean Sanders talk contribs created page Annunciator Setup - Compressor Geometry (Created page with "Optionally, the compressor geometry can be set up under the main annunciator setup, then “Inputs Setup”, then “Compressor Geometry / Performance”. <nowiki>*</nowiki>Insert Image* ''Compressor Geometry Setup'' On the left side of the page, the piston sizes can be entered to enable rod load monitoring. For each throw of the compressor enter a cylinder diameter and rod diameter for the compressor piston. If valid, the annunciator will measure the rod load of eac...") Tag: Visual edit
- 20:55, 21 July 2022 Sean Sanders talk contribs created page Annunciator Setup - No Flow Monitoring (Created page with "Up to three of the digital inputs can be used for No-Flow monitoring by connecting to a proximity switch on a lubrication divider block. This function monitors the lubrication rate of distribution blocks and shuts down the engine if a lubrication system fails. The annunciator can also monitor the average lubrication rate to determine if the system is running above or below the proper rate over time. This setup is accessed under the main annunciator setup, then “Inputs...") Tag: Visual edit
- 20:54, 21 July 2022 Sean Sanders talk contribs created page Annunciator Setup - Cylinder Temperatures (Created page with "In some applications, each cylinder on the engine will have a thermocouple. The annunciator has a special setup for this case to help make the configuration easier. On the setup page for the list of thermocouples, there is a button labeled “Cylinder Temperatures…”. This links to a page asking for the number of cylinder temperatures needed, and the labeling scheme. If cylinder temperatures are needed, set the number of cylinders to a value other than zero. Also on...") Tag: Visual edit
- 20:53, 21 July 2022 Sean Sanders talk contribs created page Annunciator Setup - Shutdown (Created page with "The Shutdown Setup (Pg. 673) can be accessed from the main annunciator setup by selecting “Outputs Setup” followed by “Shutdown Pins”, or on newer units "Outputs Status" followed by "Shutdown Pins". On this page, the type of fuel valve and ignition can be selected to show a diagram for how to wire to the shutdown pins block of the annunciator (Pins 7-10). Note that this does not actually change the functionality of the pins, it only is for viewing the correct wir...") Tag: Visual edit
- 20:53, 21 July 2022 Sean Sanders talk contribs created page Annunciator Setup - Showdown (Created page with "The Shutdown Setup (Pg. 673) can be accessed from the main annunciator setup by selecting “Outputs Setup” followed by “Shutdown Pins”, or on newer units "Outputs Status" followed by "Shutdown Pins". On this page, the type of fuel valve and ignition can be selected to show a diagram for how to wire to the shutdown pins block of the annunciator (Pins 7-10). Note that this does not actually change the functionality of the pins, it only is for viewing the correct wir...") Tag: Visual edit
- 20:51, 21 July 2022 Sean Sanders talk contribs created page Annunciator Basic Setup and Configuration Overview (Created page with "=== OVERVIEW === There are a large number of annunciator setup screens, all accessed through the Annunciator Setup Pages (Pg. 620) screen and its subpages, reached by selecting the “Annunciator Setup” button on the Annunciator Home screen. Subsequent sections of this part of the manual will describe the setup of individual parts of the system. The bulk of the setup items are under the subpage “Inputs Setup” or “Outputs Setup”. === BASIC INPUT SETUPS === The...") Tag: Visual edit
- 20:45, 21 July 2022 Sean Sanders talk contribs created page Annunciator Main User Interface Overview (Created page with "=== GENERAL OVERVIEW === The annunciator has two normal sources of user input- the EIM display and the panel switches. The general operating states and how the panel switches affect the state are as follows. With the Annunciator in the "Stopped" state, pressing the panel RESET button will reset the annunciator. This will cause the annunciator to go to the "Run" state, or move to Pre-Lube or other startup states as needed. If not in the stopped state, pressing RESET will...") Tag: Visual edit
- 20:41, 21 July 2022 Sean Sanders talk contribs created page Annunciator Installation Guide (Created page with "The installation guide can be downloaded here: https://drive.google.com/file/d/0BzOiNHLPWdg1Y0tJdS1WamdfWUU/view?usp=sharing&resourcekey=0-B9mZ3UT_q_V_-E0QsB0G7A The quick start guide can be downloaded here: https://drive.google.com/file/d/0BzOiNHLPWdg1QUlnY1g3SkdXR1U/view?usp=sharing") Tag: Visual edit
- 20:14, 21 July 2022 Sean Sanders talk contribs created page ECU Manual (Created page with "The ECU manual can be viewed/downloaded here: https://drive.google.com/open?id=14KyeKD9hayM4SeIV7c8Ia0Z-tWnjZUkZ") Tag: Visual edit
- 19:15, 21 July 2022 Sean Sanders talk contribs created page AFRC Setup (Created page with "Video available for this topic: https://www.youtube.com/watch?v=PAmjcq7CPt0 === ENGINE CONDITION === For proper AFRC operation, it is critical that the engine be in good operational status. Verify the following before running the AFRC: * Valves are adjusted to factory specification * Spark plugs are properly gapped and in good condition * Cylinders have good compression * Mixers are in good condition and regulator fuel pressure is set to factory specification * Fuel co...") Tag: Visual edit
- 18:37, 21 July 2022 Sean Sanders talk contribs created page AFRC Home Screen (Created page with "The AFRC Home screen provides all the necessary information and functionality to select the target setpoint, adjust the valve, enable/disable control, and access additional setup features. The left side of the screen is broken up into boxes which represent control for the individual banks of the engine. The right side of the screen provides a visual indication, through bar graphs, of the oxygen content of the exhaust, valve position, and catalyst temperatures. A security...") Tag: Visual edit
- 18:34, 21 July 2022 Sean Sanders talk contribs created page AFRC Installation Guide (Created page with "The installation guide can be downloaded here: https://drive.google.com/open?id=1UkusWWJOSeBmjavjdAVOUHR_ocauA2Z1 The quick start guide can be downloaded here: https://drive.google.com/file/d/0BzOiNHLPWdg1UXlaX2YzOFM0dms/view?usp=sharing&resourcekey=0-c9itYJbFwTwDKjlhv3kEDg") Tag: Visual edit
- 18:27, 21 July 2022 Sean Sanders talk contribs created page EIM Software Update (Created page with "Video available for this topic: https://www.youtube.com/watch?v=o9Mf76GIxBA * Using a Windows-based computer, transfer the EMIT-provided EIM software update file to a FAT-formatted USB thumb drive * The file name should be “EIM_update.tar” * Plug the USB thumb drive into the USB A port on the opposite side of the EIM * Within the EIM’s user interface, enter the appropriate password to for either Setup or Engineering security access * From the System Menu screen (...") Tag: Visual edit
- 18:25, 21 July 2022 Sean Sanders talk contribs created page EIM Alarms (Created page with "The EIM and associated modules are capable of identifying a wide range possible alarm conditions. Depending on the module there are a set of custom and fixed alarms in the system to generate an alarm event for the error condition. See the “ALARMS” section of any of the modules for details on how to configure an alarm. As discussed in the module alarm sections, most alarms can be set up to close the error relay and shutdown the engine on critical alarms (other than an...") Tag: Visual edit
- 18:17, 21 July 2022 Sean Sanders talk contribs created page EDR Wi-Fi Console Pages (Created page with "From the top right menu on a phone, or along the top on a computer, there will be the following page categories: Status, Compressor Master, Alerts, Engine Data Translator, Modbus Slave, and Debug. Each of these 6 pages are detailed below. === Status === The Status page shows the current readings for engine and compressor data. Settings cannot be edited on this page. Also shown under “General” is the serial number and software version. <nowiki>*</nowiki>Insert Image...") Tag: Visual edit
- 18:12, 21 July 2022 Sean Sanders talk contribs created page EDR Connecting (Created page with "Check your target device’s Wi-Fi settings for a network called “EDR_xxxx”, where xxxx is the serial number of the Data Relay. Connect to this network and enter the password ‘emitemit’. Note: There will be no internet access while you are connected to the network. It is recommended that you turn auto reconnect off. Once connected, open a web browser and type <nowiki>http://172.16.16.1/</nowiki> . This will bring up the Data Relay console. <nowiki>*</nowiki>In...") Tag: Visual edit
- 18:11, 21 July 2022 Sean Sanders talk contribs created page EDR Troubleshooting Guide (Created page with "This document covers troubleshooting steps for various EDR issues https://drive.google.com/file/d/1-gnsQWNj71XOUQYHcC5wN2dpd5X-1Hr6/view?usp=sharing") Tag: Visual edit
- 18:11, 21 July 2022 Sean Sanders talk contribs created page EDR Internal EDT Update (Created page with "The EDR has an internal EDT that is updated separately from the EDR itself. It is uncommon that it needs to be updated, but if it does follow these steps. 1. Download the latest EDT_xxxx.hex file from this page 2. Put the file on a USB drive 3. Remove the cover of the EDR by loosening the screws on one of the end caps 4. Locate the USB port near the power switch that was previously hidden <nowiki>*</nowiki>Insert Image* ''USB port location'' 5. Turn power o...") Tag: Visual edit
- 18:10, 21 July 2022 Sean Sanders talk contribs created page EDR Installation Guide (Created page with "There are install guides for different types of panels that shows the specific details for that type. The currently available install guide links are below. New combined document: https://drive.google.com/file/d/1TUEDAemMng3xTDCwqNSy16d1HOJxVciA/view?usp=sharing Murphy TTD: https://drive.google.com/file/d/1HAgyOSzoLrYLllkaGtimA7d615ya94mX/view?usp=sharing Murphy Centurion C4: https://drive.google.com/file/d/1tuuhHGA9hmNi1F7u8UZXB_T4W_WQ0ZDw/view?usp=sharing Altronic...") Tag: Visual edit
- 18:08, 21 July 2022 Sean Sanders talk contribs created page EDR Field Configuration (Created page with "Video for this topic: https://www.youtube.com/watch?v=y2lrFy0ITbQ Generally EMIT will send out the EDR already configured to communicate via Modbus to a specific panel. If the module is not configured, the guides below detail how to configure the module for a type of panel. Configuring for DE3000 Panel: https://drive.google.com/file/d/1dyrNdjfzIoRU_jQudMkycjfdVLv5qpE9/view?usp=sharing Configuring for DD40 Panel: https://drive.google.com/file/d/1ezXo-FjjVbN7KEMYP_QOT_...") Tag: Visual edit
- 17:53, 21 July 2022 Sean Sanders talk contribs created page Auto Override (Created page with "In some cases, it is useful to have the governor go to full speed during a pressure-control mode to anticipate an upcoming load change. The governor auto override allows for this. In general, starting the override mode causes the governor to enter full speed for a given time period (e.g. 3 minutes). Once this time period expires, the governor returns to normal control mode. The timer will start and count down regardless of control mode, but if the governor is not runni...") Tag: Visual edit
- 17:52, 21 July 2022 Sean Sanders talk contribs created page Throttle Calibration (Created page with "The Governor Throttle Calibration page (Pg. 523) can be used to re-calibrate the throttle body. This moves the throttle through its full range of motion and saves the values for the endpoints and also what effort is required to move the throttle. To get to this page, from the Governor Home Screen select "Setup" followed by "Throttle Calibration". The throttle will usually only need to be recalibrated if the throttle is changed. It could also help to recalibrate it if it...") Tag: Visual edit
- 17:51, 21 July 2022 Sean Sanders talk contribs created page Engineering Setup (Created page with "The Governor Advanced Setup page (Pg. 521) contains advanced settings for governor operation. An access level of ''Engineering'' is needed to use this page. A description of each setting is listed below. <nowiki>*</nowiki>Insert Image* ''Governor Advanced Setup'' Starting RPM: This is the value which the Governor uses to determine if the engine is done cranking. It would not likely need to be changed unless an engine cranks very quickly. Starting Throttle: This is th...") Tag: Visual edit
- 17:50, 21 July 2022 Sean Sanders talk contribs created page Sensor Setup (Created page with "The Governor Sensor Setup page (Pg. 520) specifies the pressure sensor settings. This duplicates the functionality on setup step 4. An access level of Setup or higher is needed to see this screen. For each sensor used, specify the low and high PSI value that corresponds to the input that causes an output of 4mA and 20mA respectively. This information can be found stamped on the sensor itself.") Tag: Visual edit