User contributions for Thomas Peterson
From EMIT Controls
8 May 2024
- 20:2220:22, 8 May 2024 diff hist +14 Annunciator Setup - Custom PID →Adjusting Direction current
- 20:0520:05, 8 May 2024 diff hist +263 Annunciator Setup - Custom PID No edit summary
6 May 2024
- 13:3613:36, 6 May 2024 diff hist +127 Remote or Auto Restart →Requirements current
11 April 2024
- 13:1013:10, 11 April 2024 diff hist 0 Spare Parts Reference →ECU Exhaust Harness current
3 April 2024
- 15:2715:27, 3 April 2024 diff hist +89 Connecting EDR to EIM with Ethernet No edit summary current Tag: Visual edit
28 March 2024
- 14:3914:39, 28 March 2024 diff hist 0 EDT stand alone table No edit summary current
27 March 2024
- 19:0919:09, 27 March 2024 diff hist +37 EDT stand alone table No edit summary
- 19:0919:09, 27 March 2024 diff hist 0 N File:Edt.jpg No edit summary current
26 March 2024
- 21:1421:14, 26 March 2024 diff hist +98 Waukesha VHP Engine Controls →Pinout Reference current
- 21:1121:11, 26 March 2024 diff hist +222 Waukesha VHP Engine Controls →Pinout Reference
- 21:0821:08, 26 March 2024 diff hist +17 Waukesha VHP Engine Controls →Throttle Actuator
- 21:0821:08, 26 March 2024 diff hist +677 Waukesha VHP Engine Controls →Pinout Reference
- 21:0021:00, 26 March 2024 diff hist +530 Waukesha VHP Engine Controls →Pinout Reference
- 20:5820:58, 26 March 2024 diff hist +722 Waukesha VHP Engine Controls →Operating Information
- 20:5020:50, 26 March 2024 diff hist +117 Waukesha VHP Engine Controls →Install Information
20 March 2024
- 19:5319:53, 20 March 2024 diff hist +38 Spare Parts Reference →Coil harnesses
- 19:5219:52, 20 March 2024 diff hist +38 Spare Parts Reference →ECU Coil Harness
13 March 2024
- 19:5919:59, 13 March 2024 diff hist +244 N EDT stand alone table Created page with "The EDT module (20350) can be used in a stand alone capacity to translate engine data to modbus without use of an EMIT screen. The Modbus list is found here: [https://drive.google.com/file/d/12hMzQQbGhOkUW418gLoFQXhgKTfeQOfM/view?usp=sharing]"
- 19:5819:58, 13 March 2024 diff hist +27 Other Topics No edit summary current
16 February 2024
- 18:1218:12, 16 February 2024 diff hist +68 Waukesha VHP Engine Controls No edit summary
- 18:1118:11, 16 February 2024 diff hist +26 Waukesha VHP Engine Controls →Ignition
- 18:1118:11, 16 February 2024 diff hist +26 Waukesha VHP Engine Controls →Speed Module
- 17:5017:50, 16 February 2024 diff hist +832 Waukesha VHP Engine Controls →Speed Module
- 17:4217:42, 16 February 2024 diff hist +10 Waukesha VHP Engine Controls →Ignition
- 17:4117:41, 16 February 2024 diff hist +13 Waukesha VHP Engine Controls →AFRC
- 17:4017:40, 16 February 2024 diff hist −1 Waukesha VHP Engine Controls →Ignition
- 17:3917:39, 16 February 2024 diff hist +1,212 Waukesha VHP Engine Controls →Ignition
- 17:3317:33, 16 February 2024 diff hist +52 Waukesha VHP Engine Controls →Ordering Information
- 17:3117:31, 16 February 2024 diff hist +2,330 N Waukesha VHP Engine Controls Created page with "== Overview == EMIT engine control products (AFRC, Ignition, and speed controller) can be used on Waukesha VHP engines of various types. These kits can replace the ESM or upgrade older engines. This page covers ordering, install, and operating information. == Ordering Information == The sections below show what AFRC, Ignition, and governor kit would be selected for different applications, and the item numbers for spare parts. === AFRC === Note that the kit item numb..."
- 17:1917:19, 16 February 2024 diff hist +34 Other Topics No edit summary
15 February 2024
- 20:2620:26, 15 February 2024 diff hist +1,471 Panel to ESM(r) Interfacing No edit summary current
- 20:1820:18, 15 February 2024 diff hist +371 Panel to ESM(r) Interfacing →ESM Data Connection
- 20:1620:16, 15 February 2024 diff hist 0 N File:Edt esm.PNG No edit summary current
- 20:1620:16, 15 February 2024 diff hist +631 Panel to ESM(r) Interfacing No edit summary
- 20:0520:05, 15 February 2024 diff hist +1,623 Panel to ESM(r) Interfacing No edit summary
- 18:1918:19, 15 February 2024 diff hist +2,313 N Panel to ESM(r) Interfacing Created page with "== Overview == The Waukesha ESM (r) is an engine control unit made by Waukesha for their VHP series engines. When a unit with an ESM is connected to an EMIT panel, the panel will use a few signals to control the start, stop, and speed of the engine. Many concepts are similar to connecting to other engines. === Initial Setup === Navigate to Settings - Brain - Outputs Setup - ECU Selection, and select "Waukesha ESM". == Panel to ESM Connections == There are three disc..."
- 18:0518:05, 15 February 2024 diff hist +33 Brain or Annunciator Overview →Other Topics current
- 18:0018:00, 15 February 2024 diff hist +101 Panel to ADEM(r) Interfacing →Start Sequence current
- 17:5917:59, 15 February 2024 diff hist +1,462 Panel to ADEM(r) Interfacing →Start Sequence
- 15:3715:37, 15 February 2024 diff hist +26 Panel to ADEM(r) Interfacing No edit summary
31 January 2024
- 18:1018:10, 31 January 2024 diff hist −42 Vibration Overview →Specifications current
- 17:4817:48, 31 January 2024 diff hist −35 Other Topics No edit summary
- 17:4717:47, 31 January 2024 diff hist −29 Other Topics No edit summary
- 17:4717:47, 31 January 2024 diff hist +119 Vibration Overview →Specifications
- 17:4517:45, 31 January 2024 diff hist −14 Main Page →Documentation Categories current
- 17:4517:45, 31 January 2024 diff hist +124 Main Page →Documentation Categories
- 17:4417:44, 31 January 2024 diff hist +23 Vibration Overview No edit summary
- 17:4417:44, 31 January 2024 diff hist 0 N File:Vib sensor.png No edit summary current
- 17:4317:43, 31 January 2024 diff hist +286 Vibration Sensor CAN Wiring No edit summary current
- 17:4117:41, 31 January 2024 diff hist 0 N File:Vib 3.png No edit summary current
- 17:4117:41, 31 January 2024 diff hist 0 N File:Vib 2.png No edit summary current
- 17:4117:41, 31 January 2024 diff hist 0 N File:Vib 1.png No edit summary current
- 17:4017:40, 31 January 2024 diff hist +695 N Vibration Sensor CAN Wiring Created page with "The EMIT vibration sensor can be wired as a 4-20mA sensor or using a CAN bus. Benefits of using the CAN bus are (1) the panel analog inputs won't be consumed and (2) more detailed data and information will be available. As mentioned in the Vibration Sensor Manual, to wire via CAN the connection must make a single daisy-chain from the panel to each sensor. If a sensor is the end of the chain (only one wire goes into each terminal) then the red termination switch wil..."
- 17:3717:37, 31 January 2024 diff hist +1,940 Vibration Overview No edit summary
- 17:3617:36, 31 January 2024 diff hist +4 N Vibration Overview Created page with "asdf" Tag: Visual edit
- 17:3517:35, 31 January 2024 diff hist +39 MediaWiki:Sidebar No edit summary current
29 January 2024
- 23:0123:01, 29 January 2024 diff hist +1,084 Dual Recycle Setup No edit summary current
- 17:1217:12, 29 January 2024 diff hist +154 Downtime Type No edit summary current
26 January 2024
17 January 2024
- 17:0517:05, 17 January 2024 diff hist 0 Spare Parts Reference →External Actuators and Related
- 17:0417:04, 17 January 2024 diff hist +64 Spare Parts Reference →External Actuators and Related
5 January 2024
- 21:2521:25, 5 January 2024 diff hist +1,414 N EDR Loopback Test Created page with "A loopback test involves setting up the EDR to communicate from its own master to slave port. This tests that both ports are functional. ==Test Instructions== * Disconnect any wires in the EDR pins 3-8 and set aside. (We recommend taping over the wires so they don't short to anything) * With two spare short wires, connect 4-7 and 5-8 600px * Connect to the EDR wifi (See here for instructions) * On the "Modbus Mas..." current
- 21:1921:19, 5 January 2024 diff hist 0 N File:Loopback.png No edit summary current
- 21:1721:17, 5 January 2024 diff hist +23 EDR Overview →Minor Topics current
15 December 2023
- 22:4722:47, 15 December 2023 diff hist +6 EDR to 20240 Connection →Background current
- 19:5819:58, 15 December 2023 diff hist +22 EDR to 20240 Connection →Wiring
- 19:5719:57, 15 December 2023 diff hist 0 File:Edr emd.png Thomas Peterson uploaded a new version of File:Edr emd.png current
- 19:5519:55, 15 December 2023 diff hist 0 N File:Edr emd.png No edit summary
- 18:3118:31, 15 December 2023 diff hist +290 EDR to 20240 Connection →Scaling
- 18:2118:21, 15 December 2023 diff hist +972 EDR to 20240 Connection No edit summary
- 18:1318:13, 15 December 2023 diff hist +1,452 N 20240 EMD Modbus Table Created page with "{| class="wikitable" |+ |- ! Register !! Description !! Pin(s) !! Offset !! Scale |- | 30001 || Thermocouple 1 Reading || 24-25 || -273 || 0.03125 |- | 30002 || Thermocouple 2 Reading || 26-27 || -273 || 0.03125 |- | 30003 || Thermocouple 3 Reading || 28-29 || -273 || 0.03125 |- | 30004 || Thermocouple 4 Reading || 30-31 || -273 || 0.03125 |- | 30005 || Thermocouple 5 Reading || 32-33 || -273 || 0.03125 |- | 30006 || Thermocouple 6 Reading || 34-35 || -273 || 0.03125 |..." current
- 18:1118:11, 15 December 2023 diff hist +28 Other Topics No edit summary
- 18:0618:06, 15 December 2023 diff hist −19 EDR to 20240 Connection →Input Numbering
- 18:0418:04, 15 December 2023 diff hist +49 EDR to 20240 Connection →Input Numbering
- 18:0418:04, 15 December 2023 diff hist +1,683 EDR to 20240 Connection →Wiring
- 17:5917:59, 15 December 2023 diff hist 0 N File:Emd therm resistor.png No edit summary current
- 17:5117:51, 15 December 2023 diff hist +1 EDR to 20240 Connection No edit summary
- 17:5117:51, 15 December 2023 diff hist +252 EDR to 20240 Connection No edit summary
- 17:3917:39, 15 December 2023 diff hist +365 N EDR to 20240 Connection Created page with "== Background == The 20240 (EMD) is a module that historically is used for ZZZZ compliance monitoring. Since it has a RS-485 slave port, it can also be used as a generic sensor to modbus translator. In a typical scenario, a 20240 and a few sensors could be added to an old annunciator panel (e.g. TTD or DD-40) to allow the EDR to send the sensor values remotely."
- 17:3617:36, 15 December 2023 diff hist +29 EDR Overview →Minor Topics
21 November 2023
- 17:3517:35, 21 November 2023 diff hist +2,396 Blowdown With Recycle Sequence →Sequence Setup current
- 17:3417:34, 21 November 2023 diff hist +1,095 N Blowdown With Recycle Sequence Created page with "==Overview== The Dynamic Control panels have three options related to relieving pressure on a unit: #Blowdown vent, with a simple vent, usually to atmosphere or combuster #Blowdown to header with recycle, where suction and recycle valves are used to relieve to header #Off skid bypass, where an off-skid on/off valve is used to relieve pressure to the header This article covers option (2). ==Setting Up Valves== Before enabling this option, the valve(s) must be configu..."
- 17:3317:33, 21 November 2023 diff hist 0 N File:Blowdown recycle.png No edit summary current
- 17:2817:28, 21 November 2023 diff hist +36 Brain or Annunciator Overview →Other Topics
- 17:2817:28, 21 November 2023 diff hist +65 Annunciator Blowdown Setup No edit summary current
- 17:1117:11, 21 November 2023 diff hist +557 Troubleshooting →Engine shuts down on fault “DI-27 ADEM RUN STATUS”, even though the ADEM doesn’t show a fault code current
- 16:5216:52, 21 November 2023 diff hist +174 Panel to ADEM(r) Interfacing →Overview
- 16:5116:51, 21 November 2023 diff hist +16 MediaWiki:Sidebar No edit summary
- 16:5016:50, 21 November 2023 diff hist +19 MediaWiki:Sidebar No edit summary
- 16:4716:47, 21 November 2023 diff hist +7 Troubleshooting →Startup fails with “ECU fails to start” but the unit never tries to start (CAT engines)
- 16:4616:46, 21 November 2023 diff hist +4 Troubleshooting →Startup fails with “ECU fails to start” but the unit never tries to start (CAT engines)
- 16:4616:46, 21 November 2023 diff hist −2 Troubleshooting →Startup fails with “ECU fails to start” but the unit never tries to start (CAT engines)
- 16:4516:45, 21 November 2023 diff hist +252 Troubleshooting →Engine shuts down on fault normally, but manual stop causes the shutdown to get stuck
- 16:4416:44, 21 November 2023 diff hist +519 Troubleshooting →Startup fails with “ECU fails to start” but the unit never tries to start (CAT engines)
- 16:4216:42, 21 November 2023 diff hist +837 Panel to ADEM(r) Interfacing →Start / Stop / Fault Control
- 16:4116:41, 21 November 2023 diff hist +3,176 Troubleshooting →Startup fails with “ECU fails to start” but the unit never tries to start (CAT engines)
- 15:5915:59, 21 November 2023 diff hist +1,090 Troubleshooting →Startup fails with “ECU fails to start” but the unit never tries to start (CAT engines)
- 15:5115:51, 21 November 2023 diff hist +1,333 Troubleshooting →Control Issues
- 15:3715:37, 21 November 2023 diff hist +2,834 Troubleshooting →Control Issues
16 November 2023
- 15:3115:31, 16 November 2023 diff hist +129 N Vibration Sensor Manual Created page with "The vibration sensor manual can be found here: https://drive.google.com/file/d/1GtnchWYcN2z88KCwxIXc63ATjVz1AwDg/view?usp=sharing" current
- 15:3015:30, 16 November 2023 diff hist +29 Other Topics No edit summary
9 November 2023
- 21:1121:11, 9 November 2023 diff hist +22 EDR Installation Guide No edit summary current
- 21:1121:11, 9 November 2023 diff hist 0 EDR Installation Guide No edit summary
3 November 2023
- 16:2016:20, 3 November 2023 diff hist −55 Troubleshooting →Startup fails with “ECU fails to start”
- 16:1716:17, 3 November 2023 diff hist +425 Troubleshooting →Startup fails with “ECU fails to start”
- 16:1516:15, 3 November 2023 diff hist −228 Troubleshooting →Startup fails with “ECU fails to start”
- 16:1416:14, 3 November 2023 diff hist +273 Troubleshooting →Startup fails with “ECU fails to start”
2 November 2023
- 15:1015:10, 2 November 2023 diff hist −31 Controls Tips Newsletter Archive →November 2, 2023 current
- 15:0915:09, 2 November 2023 diff hist +2,111 Controls Tips Newsletter Archive No edit summary
- 14:4814:48, 2 November 2023 diff hist +153 Light Tower Work Around No edit summary current
- 14:4714:47, 2 November 2023 diff hist +691 N Light Tower Work Around Created page with "If an old Brain is swapped out in a panel with a new light tower, the color segments may not work. The Brain will still operate normally otherwise. If a work-around is needed, these steps can be used to get the color segments working. # Remove light tower wires from pins 64-66 (Black, Brown, White). Leave 63 and 67 connected (Blue and Gray). # Add three relays (or use spares in the panel), with each A2- connected to ground and A1+ connected to pins 64,65,66. # On each r..."
- 14:3214:32, 2 November 2023 diff hist +1,346 N Light Tower Change Created page with "==Overview== In Q4 2023 EMIT is changing from the K30 Banner light tower to K50 series. This new tower will have a built in buzzer which eliminates a separate buzzer component, and also has better visibility in bright sunlight. ==Wiring== The old and new wiring are shown below. File:Lt_old.png File:Lt new.png With the old light tower the tower had a 4-wire harness, with three wires going to pins 64-66 of the brain and the blue wire going to a ground lug. Se..." current
- 14:2714:27, 2 November 2023 diff hist 0 N File:Lt new.png No edit summary current
- 14:2614:26, 2 November 2023 diff hist 0 N File:Lt old.png No edit summary current
- 14:1914:19, 2 November 2023 diff hist +24 Other Topics No edit summary
- 14:0714:07, 2 November 2023 diff hist +2 Adding a Run Status Output No edit summary current
- 14:0714:07, 2 November 2023 diff hist +70 Adding a Run Status Output No edit summary
- 14:0514:05, 2 November 2023 diff hist +738 Adding a Run Status Output No edit summary
- 14:0314:03, 2 November 2023 diff hist 0 N File:Run status custom do.png No edit summary current
- 13:5713:57, 2 November 2023 diff hist +648 N Adding a Run Status Output Created page with "A run status output is powered on when the unit is running. It can be used to signal some other PLC or device that the unit is running. There are two ways to add the output depending on version, detailed below. ''If the Brain version is at least 2563 and DCT version 1.60'' For new versions, there is a built in option for run status. Navigate to Settings - Brain - Output Setups - Digital Output Function Selection. Select the Digital Out to use for this feature, and sc..."
- 13:4713:47, 2 November 2023 diff hist +32 Brain or Annunciator Overview →Other Topics
- 13:4213:42, 2 November 2023 diff hist +624 Annunciator Digital Output Function Selection No edit summary current
- 13:3313:33, 2 November 2023 diff hist +16 Annunciator Digital Output Function Selection No edit summary
30 October 2023
- 19:3819:38, 30 October 2023 diff hist 0 Unit Reports →Multi-Unit Reports current
- 19:3819:38, 30 October 2023 diff hist −27 Unit Reports →Multi-Unit Reports
- 19:3719:37, 30 October 2023 diff hist +23 Portal Overview →Alerts Tab current
- 19:3619:36, 30 October 2023 diff hist +189 Downtime Type →Editing the Down Time Type
- 19:3519:35, 30 October 2023 diff hist +86 Downtime Type No edit summary
- 19:3419:34, 30 October 2023 diff hist +1,084 N Downtime Type Created page with "== Overview == Several reports on the EMIT Connect Portal will categorize downtime hours into Mechanical or Production caused. The source of this sorting is the "Down Time Type" column of a unit "Alerts" tab. When an alert occurs the site will try and sort the alert based on the description into "Mechanical (Auto-Generated)" or "Production (Auto-Generated)". The sorting is based on hard-coded rules of thumb, but some shutdown descriptions will always be ambiguous. Beca..."
- 19:3219:32, 30 October 2023 diff hist 0 N File:Downtimetype.png No edit summary current
- 19:2519:25, 30 October 2023 diff hist +19 Telematics Overview →Telematics Documents and Guides current
25 October 2023
- 17:2617:26, 25 October 2023 diff hist −3 Remote or Auto Restart →Remote or Auto Restart Main Setup Tag: Visual edit
- 17:2517:25, 25 October 2023 diff hist +1,085 Remote or Auto Restart →Remote or Auto Restart Main Setup
- 17:1817:18, 25 October 2023 diff hist +212 Annunciator Bypass Setup →Basic Bypass Setup current
- 17:1717:17, 25 October 2023 diff hist 0 N File:Bypass1b.png No edit summary current
- 17:1617:16, 25 October 2023 diff hist +160 Remote or Auto Restart →Start Sequence
- 17:1217:12, 25 October 2023 diff hist +11 Remote or Auto Restart →Fault Stop Sequence
- 17:1117:11, 25 October 2023 diff hist −9 Remote or Auto Restart →Start Sequence
- 17:1017:10, 25 October 2023 diff hist +132 Remote or Auto Restart →Start Sequence
- 17:0917:09, 25 October 2023 diff hist −157 Remote or Auto Restart →Start Sequence
- 17:0817:08, 25 October 2023 diff hist +271 Remote or Auto Restart →Requirements
- 16:5216:52, 25 October 2023 diff hist +116 Remote or Auto Restart →Overview
- 16:5116:51, 25 October 2023 diff hist +12 Remote or Auto Restart →Remote or Auto Restart Main Setup
- 16:5116:51, 25 October 2023 diff hist +4 Remote or Auto Restart →Remote or Auto Restart Main Setup
- 16:5016:50, 25 October 2023 diff hist +1,740 Remote or Auto Restart →Remote or Auto Restart Main Setup
- 16:4816:48, 25 October 2023 diff hist 0 N File:Restart2.png No edit summary current
- 16:4816:48, 25 October 2023 diff hist 0 N File:Restart1.png No edit summary current
- 16:4716:47, 25 October 2023 diff hist +8,452 N Remote or Auto Restart Created page with "== Overview == EMIT ETS and Dynamic Control panels can be configured to automate the start and load sequence through settings related to various valves around the skid. If the unit is configured to load automatically, it can also be configured to be started remotely and/or automatically restart on certain faults. This document describes the sequence and configuration for these scenarios. A separate document “DC Valve Setup Guide” covers each valve setup individually..."
- 16:3916:39, 25 October 2023 diff hist +28 Brain or Annunciator Overview →Other Topics
18 October 2023
- 19:4019:40, 18 October 2023 diff hist +33 Annunciator Input Calibration →Overview current
17 October 2023
- 21:3521:35, 17 October 2023 diff hist +952 N Ignition External Timing Adjustment Created page with "The manifold pressure input pin of the ICM (4-20mA) can be repurposed to instead act as an external timing adjustment. This can be used to connect 3rd-party devices to the ICM to change timing. This feature requires Ignition version 3801+ and DCT version 1.63.871+. To use, navigate to Settings - Ignition - "External Input as Timing Adjustment". File:TimingAdj screenshot.png To enable the feature, select "Yes" on the top of this page. Next, enter the values that t..." current
- 21:3021:30, 17 October 2023 diff hist 0 N File:TimingAdj screenshot.png No edit summary current
- 21:2921:29, 17 October 2023 diff hist +41 ICM Overview →Ignition Documents and Guides current
10 October 2023
- 15:2315:23, 10 October 2023 diff hist +12 Connecting EDR to EIM with Ethernet No edit summary
4 October 2023
- 16:3516:35, 4 October 2023 diff hist +34 Annunciator Setup - Class B & C Timers No edit summary current
- 16:3316:33, 4 October 2023 diff hist 0 N File:B-C-page.PNG No edit summary current
28 September 2023
- 15:2715:27, 28 September 2023 diff hist −69 Spare Parts Reference →Panel Internal Parts Tag: Manual revert
- 14:4514:45, 28 September 2023 diff hist +69 Spare Parts Reference →Panel Internal Parts Tag: Reverted
- 14:4314:43, 28 September 2023 diff hist +58 Spare Parts Reference →Panel Internal Parts
13 September 2023
- 21:4221:42, 13 September 2023 diff hist +683 Annunciator Miscellaneous Settings No edit summary current
- 21:2321:23, 13 September 2023 diff hist +582 Unit Reports No edit summary
- 21:2021:20, 13 September 2023 diff hist +12 Unit Reports →Report Contents
- 21:1621:16, 13 September 2023 diff hist +348 Portal Overview →Alerts Tab
- 20:4920:49, 13 September 2023 diff hist +411 Portal Overview →Alerts Tab
- 20:4720:47, 13 September 2023 diff hist 0 N File:Connect-alerts-2.PNG No edit summary current
29 August 2023
- 20:0720:07, 29 August 2023 diff hist +13 DCT Panel Switch Connections →Software Version Requirements current
- 19:5919:59, 29 August 2023 diff hist +6 DCT Panel Switch Connections →Field Swap Implication
- 19:5419:54, 29 August 2023 diff hist +453 DCT Config Files →Overview current
- 19:5219:52, 29 August 2023 diff hist −8 DCT Config Files →Overview
22 August 2023
- 21:1821:18, 22 August 2023 diff hist 0 AFRC Overview →Overview current
31 July 2023
21 July 2023
- 21:3921:39, 21 July 2023 diff hist +188 Troubleshooting →Engine shuts down on fault “DI-27 ADEM RUN STATUS”, even though the ADEM doesn’t show a fault code
- 21:3821:38, 21 July 2023 diff hist +120 Troubleshooting →Startup fails with “ECU fails to start”
- 21:3521:35, 21 July 2023 diff hist −12 Troubleshooting →Digital output issues
- 21:3121:31, 21 July 2023 diff hist +113 Troubleshooting →Speed control output incorrect
- 21:2921:29, 21 July 2023 diff hist +119 Annunciator Fault & Output Status Screen →Overview current
- 21:2721:27, 21 July 2023 diff hist +18 Troubleshooting →MPU input reading incorrectly
- 21:2621:26, 21 July 2023 diff hist +94 Troubleshooting →Digital input reading incorrectly
- 21:2521:25, 21 July 2023 diff hist +4 Troubleshooting →Digital input reading incorrectly
- 21:2421:24, 21 July 2023 diff hist +191 Troubleshooting →Digital input reading incorrectly
- 21:2221:22, 21 July 2023 diff hist +11 Troubleshooting →Thermocouple inputs reading incorrectly
- 21:2121:21, 21 July 2023 diff hist +98 Troubleshooting →4-20 mA Analog input issues
- 21:0521:05, 21 July 2023 diff hist +1,147 Troubleshooting No edit summary
- 20:5820:58, 21 July 2023 diff hist +1,830 Troubleshooting →Brain / Annunciator / Brain+ 20320 20330
- 20:5720:57, 21 July 2023 diff hist +1,526 Troubleshooting →Output Issues
- 20:5720:57, 21 July 2023 diff hist 0 N File:Fv2.png No edit summary current
- 20:5620:56, 21 July 2023 diff hist 0 N File:Fv1.png No edit summary current
- 20:5520:55, 21 July 2023 diff hist +135 Troubleshooting →Digital output issues
- 20:5420:54, 21 July 2023 diff hist 0 N File:Ann do on.png No edit summary current
- 20:5420:54, 21 July 2023 diff hist 0 N File:Ann do off.png No edit summary current
- 20:5320:53, 21 July 2023 diff hist +7,581 Troubleshooting No edit summary
- 20:5120:51, 21 July 2023 diff hist 0 N File:Ann ai.png No edit summary current
- 20:4820:48, 21 July 2023 diff hist +4,211 Troubleshooting No edit summary
- 20:4320:43, 21 July 2023 diff hist +4 Troubleshooting →Shutdown pin input not working / Ignition is not in "External shutdown" when engine is off
- 20:4320:43, 21 July 2023 diff hist 0 File:ICM sd wiring.png Thomas Peterson uploaded a new version of File:ICM sd wiring.png current
- 20:4120:41, 21 July 2023 diff hist −1 Troubleshooting →Hall sensor not moving
- 20:4120:41, 21 July 2023 diff hist +5,899 Troubleshooting →Ignition 20270
- 20:3620:36, 21 July 2023 diff hist 0 N File:ICM sd wiring.png No edit summary
- 20:3520:35, 21 July 2023 diff hist +1,514 Troubleshooting →Hall sensor not moving
- 18:5918:59, 21 July 2023 diff hist +2,296 Troubleshooting No edit summary
- 18:5918:59, 21 July 2023 diff hist 0 N File:Icm hall threaded.png No edit summary current
- 18:5818:58, 21 July 2023 diff hist 0 N File:Icm hall 330x.png No edit summary current
- 18:5718:57, 21 July 2023 diff hist 0 N File:Icm mpu.png No edit summary current
- 17:2917:29, 21 July 2023 diff hist +8 Troubleshooting →RPM Reads “0” when cranking
- 17:2817:28, 21 July 2023 diff hist +3,980 Troubleshooting →Governor / Speed Controller 20310
- 17:2517:25, 21 July 2023 diff hist +1,561 Troubleshooting →Panel switches reading incorrectly
- 17:2417:24, 21 July 2023 diff hist 0 N File:Ts 1 1 6.png No edit summary current
- 17:2017:20, 21 July 2023 diff hist +6,429 Troubleshooting No edit summary
- 17:1917:19, 21 July 2023 diff hist 0 N File:GovV.png No edit summary current
- 17:1617:16, 21 July 2023 diff hist 0 N File:GovMpuICM.png No edit summary current
- 17:1417:14, 21 July 2023 diff hist 0 N File:GovMpuPanel.png No edit summary current
- 17:1317:13, 21 July 2023 diff hist 0 N File:GovmpuBasic.png No edit summary current
- 16:5916:59, 21 July 2023 diff hist +152 EDT in DCT update No edit summary current
- 14:1714:17, 21 July 2023 diff hist +49 Troubleshooting →EIM 20200
- 14:1214:12, 21 July 2023 diff hist +1,432 N Troubleshooting Created page with "== EIM 20200 == === Screen boots to the EMIT logo, but is stuck there === * Usually this is an issue with the internal memory and must be repaired by EMIT * The SLC-SD card lock may be grounded against the case * The SLC-SD card itself may have an issue === Screen boots past the EMIT logo, but the application does not start === * Usually this will require repair * An SLC-SD card from a different EIM was used and the encryption does not match (Cards cannot be swapped be..."
- 14:1014:10, 21 July 2023 diff hist 0 N File:Eim bl.jpg No edit summary current
- 14:0514:05, 21 July 2023 diff hist +21 Other Topics No edit summary
20 July 2023
- 20:4820:48, 20 July 2023 diff hist 0 Special Compressor Oil Pressure Alarm →Using the Alarm current
- 20:4420:44, 20 July 2023 diff hist 0 Special Compressor Oil Pressure Alarm No edit summary
13 July 2023
- 16:4916:49, 13 July 2023 diff hist +99 Annunciator Setup - Home Page Gauges →Special Gauges current
- 16:3916:39, 13 July 2023 diff hist +3 EIM Read Fix No edit summary current
- 16:3216:32, 13 July 2023 diff hist +9 Viewing Brain Configuration Warnings No edit summary current
- 16:3116:31, 13 July 2023 diff hist +2 Annunciator Testing Mode No edit summary current
- 16:2716:27, 13 July 2023 diff hist +148 DCT Software Update No edit summary current
6 July 2023
- 19:0719:07, 6 July 2023 diff hist −10 EIM System Settings or Utilities Pages →Datalog Files current
- 19:0619:06, 6 July 2023 diff hist +130 EIM System Settings or Utilities Pages →Reset
- 19:0519:05, 6 July 2023 diff hist −64 EIM System Settings or Utilities Pages →Software Update
- 19:0319:03, 6 July 2023 diff hist +57 EIM System Settings or Utilities Pages →Go To Page
- 18:4718:47, 6 July 2023 diff hist 0 Guest Access →Overview current
- 17:4617:46, 6 July 2023 diff hist +25 EIM Read Fix No edit summary
5 July 2023
- 18:2718:27, 5 July 2023 diff hist +71 Special Compressor Oil Pressure Alarm →Alarm Logic
- 18:2618:26, 5 July 2023 diff hist +8 Special Compressor Oil Pressure Alarm →Alarm Logic
- 18:2618:26, 5 July 2023 diff hist −14 Special Compressor Oil Pressure Alarm →Alarm Logic
- 18:2518:25, 5 July 2023 diff hist +5 Special Compressor Oil Pressure Alarm →Alarm Logic
- 18:2518:25, 5 July 2023 diff hist +2 Special Compressor Oil Pressure Alarm →Alarm Logic
- 18:2418:24, 5 July 2023 diff hist −4 Special Compressor Oil Pressure Alarm No edit summary
- 18:2318:23, 5 July 2023 diff hist +13 Special Compressor Oil Pressure Alarm No edit summary
- 18:2118:21, 5 July 2023 diff hist +1,199 N Special Compressor Oil Pressure Alarm Created page with "==Overview== Typically the compressor oil pressure will have the low alarm on the "B2" timer, which will be set to 15 - 30 seconds. However if the oil pump is not working then there could be damage by the time the B2 timer expires and the unit shuts down. To address this, a special alarm was added to Brain v2773 to catch when the engine starts cranking but the compressor oil pressure is not building. ==Using the Alarm== To use the alarm: #Make sure the Brain is at v2..."
- 18:1218:12, 5 July 2023 diff hist +43 Brain or Annunciator Overview →Other Topics
29 June 2023
- 14:2114:21, 29 June 2023 diff hist +34 Viewing Brain Configuration Warnings →Viewing Warnings
- 14:1814:18, 29 June 2023 diff hist +801 Viewing Brain Configuration Warnings No edit summary
- 14:1514:15, 29 June 2023 diff hist +2 Viewing Brain Configuration Warnings →Viewing Warnings
- 14:1414:14, 29 June 2023 diff hist +13 Viewing Brain Configuration Warnings →Viewing Warnings
- 14:1314:13, 29 June 2023 diff hist +124 Viewing Brain Configuration Warnings →Viewing Warnings
- 14:1314:13, 29 June 2023 diff hist +18 Viewing Brain Configuration Warnings →Viewing Warnings
- 14:1114:11, 29 June 2023 diff hist +56 Viewing Brain Configuration Warnings →Viewing Warnings
- 14:1014:10, 29 June 2023 diff hist +17 Viewing Brain Configuration Warnings →Overview
- 14:0914:09, 29 June 2023 diff hist +555 Viewing Brain Configuration Warnings →Viewing Warnings
- 14:0714:07, 29 June 2023 diff hist 0 N File:Connect unit warning.png No edit summary current
- 14:0614:06, 29 June 2023 diff hist 0 N File:Connect unit issues.png No edit summary current